NED
UME-0022-0
2
XCM80160CXP_60160CXP_40160CXP
31
5.3.7 Memory Initializing (Initializing Camera Settings)
Reset the flash memory to the factory default.
・
Register name
User Set_Reset to Factory Default
・
VAL Execute()
5.3.8 Memory Load (Reads out the camera settings from the flash
memory
)
Reads out the camera settings from the flash memory
・
Register name
User Set_Load
・
VAL Execute()
5.3.9 Memory Save
Stores current camera settings in the flash memory.
・
Register name
User Set_Save
・
VAL Execute()
5.3.10 Generating Test Pattern
Generates test pattern.
・
Register name
Test Image Selector
・
VAL
Off / GreyHorizontalRamp
(Example)
TestImageSelector: GreyHorizontalRamp
5.3.11 Saving Pixel Correction Data
Acquires current pixel correction data and saves it in the flash memory. One set of
correction data can be saved for each step of analog gain.
・
Register name
Pixel Correct Data Save
VAL Execute()