background image

USER INSTRUCTIONS 

1. GENERAL POINTS 

 

 

 

Before use of this appliance please read these instructions 
fully. 

WARNING: ANY MODIFICATION OF THE APPLIANCE THAT 
HAS NOT BEEN APPROVED IN WRITING BY THE TESTING 
AUTHORITY IS CONSIDERED AS BREACHING AS/NZS 4013. 

WARNING: DO NOT USE FLAMMABLE LIQUIDS OR AERO-
SOLS TO START OR REKINDLE THE FIRE. 

WARNING: DO NOT USE FLAMMABLE LIQUIDS OR AERO-
SOLS IN THE VICINITY OF THIS APPLIANCE WHEN IT IS OP-
ERATING. 

WARNING: DO NOT STORE FUEL WITHIN HEATER INSTAL-
LATION CLEARANCES. 

WARNING: WHEN OPERATING THIS APPLIANCE AS AN 
OPEN FIRE USE A FIRE SCREEN. 

WARNING: OPEN AIR CONTROL (AND DAMPER WHEN FIT-
TED) BEFORE OPENING FIRING DOOR. 

CAUTION: THIS APPLIANCE SHOULD NOT BE OPERATED 
WITH A CRACKED GLASS. 

CAUTION: THIS APPLIANCE SHOULD BE MAINTAINED AND 
OPERATED AT ALL TIMES IN ACCORDANCE WITH THESE IN-
STRUCTIONS. 

CAUTION: THE USE OF SOME TYPES OF PRESERVATIVE-
TREATED WOOD AS A FUEL CAN BE HAZARDOUS. 

The appliance or flue system should not be modified in any 
way without the written approval of the manufacturer. 

Extractor fans or cooker hoods must not be placed in the 
same room or space as this can cause appliance to emit 
smoke into the room. 

 

SERIAL NUMBER

 

This number is required when ordering spare parts or mak-
ing warranty claims. This can be found on the appliance 
specification label on the rear heat shield 

Refer to photo below for location of serial number. 

 

 

 

 

 

 

 

 

 

AIR CONTROLS 

Cleanburn technology and greater efficiency 

The air spindle on the door controls the primary air to the 
base of the fire. This controls the burn rate of the fire.  

A tool for opening and closing the air spindle is supplied 
with the heater. This can be used in instances when the 
spindle control is too hot to touch. Alternatively, a glove or 
equivalent can be used to adjust the air spindle. 

 

 

 

 

 

 

 

 

A 2mm gap at the top of the door allows additional second-
ary air to enter the firebox, washing over the door glass 
keeping it clean while also supplying necessary oxygen to 
the fire when the air spindle has been fully closed. 

If required, the 2mm gap can be adjusted by loosening the 
two grub screws in the top of the door (high-lighted in photo 
below) with the Allen key supplied, adjusting the metal strip 
accordingly and re-tightening the screws.  

 

 

 

 

 

 

 

 

DOOR HANDLE 

Warning: door handle may get hot if appliance has been left 
in High burn setting for extended period of time. In which 
case use a protective glove or equivalent to open. 

Open air spindle before opening door to eliminate chance of 
backdraft. 

 

Summary of Contents for Nectre 15

Page 1: ...rating Instructions Efficient Warm Friendly Manufactured in Australia Keep instructions in a safe place for future reference Pecan Engineering Pty Ltd proudly supports the activities of Landcare Austr...

Page 2: ...unning the Appliance 4 6 Burning Tips 5 7 Ash Removal 5 8 Flue Chimney Fire 5 9 Cleaning Paint Work and Glass 6 10 Flue Cleaning 6 11 Troubleshooting Tips 6 MAINTENANCE SERVICING 7 1 Replacement of Fi...

Page 3: ...smoke into the room SERIAL NUMBER This number is required when ordering spare parts or mak ing warranty claims This can be found on the appliance specification label on the rear heat shield Refer to p...

Page 4: ...and the glass warms to avoid the build up of condensation Add larger pieces of wood Too many logs may smother the fire Close the door The appliance works optimally when there is a layer of ash in the...

Page 5: ...eosote within the appliance and flue Flue Draught The flue has two main functions 1 To safely remove smoke gases and fumes from the ap pliance 2 To provide a sufficient amount of draught suction in th...

Page 6: ...e door seal has settled in The gap at the top of the door should be 2mm This can be checked with the Allen key provided as it is 2mm thick If adjustment is required loosen the two grub screws on the t...

Page 7: ...he door glass i Remove the four M4 size Phillips head screws on either side along with the stainless steel strips holding the glass in place ii Take out the glass and check if the grey rope beneath ne...

Page 8: ...not apply to firebricks brick retainer baffle door seal glass nor discolouration of the surface or tarnishing of chrome fittings all of which require normal service to maintain them Under the terms o...