1 - 410
MIF (LCR) Assignment
NEC Business Solutions Ltd
Xen Master & Xen Axis
A
6
-324000-
642-
02 - Release 6.0
May 20
03
7-3-01
System Mode
7
MIF
3
Data No.
01
PC Programming
a
+BS
MIF (LCR) Assignment
General Description
Use this Memory Block to enable the Least Cost Routing (LCR) function of the MIFM-U13
ETU.
Display
Programming Procedures
1
Go off-line.
2
Press LK7 + LK3 +
KA
to access the Memory Block.
3
Use the dial pad to enter data.
Note:
Use the following to enter data:
J
to move the cursor left
L
to move the cursor right
K
~
I
to enter numeric data
Setting Data 00, 01, 02
Default Values
No Assignment (00)
4
Press
N
to write the data.
5
Press
P
to go back on-line.
Related Programming
No related programming is necessary for this Memory Block.
N
1. The LCR feature requires a KMM(1.0)U unit to be installed on the MIFM-U13 ETU.
2. SMDR feature is enabled automatically when LCR is set to 01.
0 1 : L C R
M I F = 0 0
T I M E
D I S P L A Y
Data
No.
Title
Setting
Data