![NEC WMK-3257 Installation And Assembly Manual Download Page 5](http://html.mh-extra.com/html/nec/wmk-3257/wmk-3257_installation-and-assembly-manual_251044005.webp)
5 of 7
ISSUED: 03-26-10 SHEET #: 125-9106-6 12-11-14
1
3
2
concrete
surface
Installation to Solid Concrete or Cinder Block
1
Make sure that wall plate (
A
) is level, use it as a
template to mark four mounting holes. Drill four
5/16" (8 mm) dia. holes to a minimum depth of 2.5"
(64 mm). Insert anchors (
E
) in holes fl ush with wall
as shown (right). Place wall plate over anchors
and secure with #14 x 2.5" screws (
D
). Level, then
tighten all fasteners.
• When installing Peerless wall mounts on a concrete wall, the wall must be at least 8" thick with a minimum compres-
sive strength of 2000 psi.
• When installing Peerless wall mounts on a cinder block wall, the cinder blocks must meet ASTM C-90 specifi cations
and have a minimum nominal width of 8". Do not drill into mortar joints! Be sure to mount in a solid part of the block,
generally 1" (25 mm) minimum from the side of the block. It is suggested that a standard electric drill on slow setting
is used to drill the hole instead of a hammer drill to avoid breaking out the back of the hole when entering a void or
cavity.
• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard-
ware and components.
WARNING
• Always attach concrete anchors directly to load-
bearing concrete.
• Never attach concrete anchors to concrete covered
with plaster, drywall, or other fi nishing material.
WARNING
• Tighten screws so that wall plate is fi rmly attached,
but do not overtighten. Overtightening can damage
screws, greatly reducing their holding power.
• Never tighten in excess of 80 in. • lb (9 N.M.).
WARNING
D
A
E
solid concrete
cinder block
E
D
E
A
Drill holes and insert anchors (
E
).
Place plate (
A
) over anchors (
E
) and secure with screws (
D
).
Tighten all fasteners.