CHAPTER 1 OVERVIEW
User’s Manual U15447EJ1V0UM
12
1.4
System Configuration
The system configuration when connecting the IE-703002-MC to the IE-703079-MC-EM1 and a personal computer
(PC-9800 series or PC/AT (or compatibles)) is shown below.
Figure 1-1. System Configuration
Remark
<1> Personal computer (PC-9800 series or PC/AT or compatibles)
<2> Debugger (ID850: sold separately)
<3> PC interface board
(IE-70000-98-IF-C/IE-70000-PC-IF-C, IE-70000-PCI-IF-A/IE-70000-CD-IF-A: sold separately)
<4> PC interface cable (included with IE-703002-MC)
<5> In-circuit emulator (IE-703002-MC: sold separately)
<6> In-circuit emulator option board (IE-703079-MC-EM1: this product)
<7> External logic probe (included with IE-703002-MC)
<8> Socket for target connection (YQSOCKET100SDN: sold separately)
<9> Extension probe (for GC package: SWEX-100SD, for GF package: SWEX-100SD/GF-N17DT)
<10> Connector for emulator connection (YQPACK100SD: included)
<11> Connector for target connection (NQPACK100SD: included)
<12> Power adapter (IE-70000-MC-PS-B: sold separately)
<13> AC100V power cable (sold separately: included with IE-70000-MC-PS-B)
<14> AC220V power cable (sold separately: included with IE-70000-MC-PS-B)
[Magnified drawing: example of use of
connector for target connection]
Target
system
<13>
<14>
<12>
<5>
<6>
<7>
<4>
<3>
<1>, <2>
<9>
<11>
<10>
Target system
<10>
<11>
<8>