General
1) Power Requirement
Type 1
±48VDC (±36V to ±60V)
Type 2
±24VDC (±20V to ±60V (option))
2) Power Consumption
1+0:
1+1:
6 – 8 GHz
75 W
150 W
11 – 38 GHz
55 W
110 W
(typical)
(typical)
3) Temperature Range
Guaranteed operation IDU
: -5
°
C to +50
°
C
ODU
: -33
°
C to +50
°
C
Workable operation
IDU
: -10
°
C to +55
°
C
ODU
: -40
°
C to +55
°
C
Transport and storage
IDU
: -40
°
C to +70
°
C
ODU
: -40
°
C to +70
°
C
4) Relative humidity
IDU : Less than 90% at 50
°
C (Non-condensing)
ODU : 100% applicable
5) Altitude
Up to 4,000 m
6) Interconnection between ODU and IDU
Interconnection
: Single coaxial cable/Impedance = 50 ohms
Type of cable
: 5D-FB, 8D-FB, 10D-FB, 12D-FB or Equivalent cable
Signals
: IF signal, alarms control, monitoring
power source, and, orderwire
Maximum cable length*
: 150 m (5D-FB)
300 m (8D-FB)
350 m (10D-FB)
450 m (12D-FB)
Cable equalization
: Automatic level equalization
Note* : In case of hitless protection, set each length of two IF cables to same and not to
exceed 100 meters.