PASOLINK
+
155 MB 1+0/1+1 SYSTEM
MTD-PL-028/141005
- 26 -
1+1 Equipment
LED indication
Condition
Color
MAINT
During maintenance
Yellow
ODU ALM1
ODU No.1 Equipment fail
Red
IDU ALM1
IDU No.1 Equipment fail
Red
ODU ALM2
ODU No.2 Equipment fail
Red
IDU ALM2
IDU No.2 Equipment fail
Red
PWR1
No.1: On power
Green
PWR2
No.2 : On power
Green
TX1
No.1 TX output
Green
TX2
No.2 TX output
Green
RX1
No.1 RX selected
Green
RX2
No.2 RX selected
Green
Note: The same fails of No.1/No.2 indicate IDU ALM1 and IDU ALM2 at the same time.
TX1/2 and RX1/2 indication available only in case of 1+1 IDU.
6.7
House Keeping Alarm/Control Interface
Data In/Data Out (DI/DO) for house keeping alarms or controls are available with LCT setting.
DI/DO item number is changeable by setting LCT configuration.
DI
DO
Comments
6 ports
4 ports (Max)
DI : DI interfaces are included in ALM/AUX connector.
DO: Refer to next page “alarm output connection table”.
Port condition
DI INPUT Logic
: Normal OPEN (
>
200 kohms)
DO OUTPUT logic
: Controlled from PNMS/T
Event CLOSE (
<
50 ohms)
Interface circuit
: Relay Form C
Interface circuit : Photo coupler with bias circuit
Maximum Current
: 0.2 A
OUTPUT Device : Indicates Status on PNMS/T
Maximum Voltage : 100 V (AC + DC)
.
+3.3 V
+3.3 V
Open
Close
Event Close
Relay
Event Open
Event Close
COM
Summary of Contents for PASOLINK+