ISSUED: 04-11-06  SHEET #: 055-9458-1

Visit the NEC Web Site at  www.necsam.com

6 of 9

For customer care call 1-800-729-0307 or 708-865-8870.

Drill two 1/4" (6 mm) dia. holes to a minimum depth of
2.5" (64 mm). Attach ceiling plate (G) using two
concrete anchors and #14 x 2.5" wood screws (F) as
shown in Illustration A and 12, and (below).
Tighten all fasteners.

IMPORTANT: It is the responsibility of the installer
to verify that the ceiling will safely support the
combined load of all attached hardware and
components.

1

3

CUT

A

W

A

Y

 VIEW

INCORRECT

concrete

metal

bracket

plaster/
dry wall

CORRECT

concrete

metal

bracket

plaster/
dry wall

concrete
ceiling

concrete
anchor

concrete
anchor

concrete
anchor

F

F

Illustration A

Installation to Concrete Ceilings

ACC 203 (Alligator

® 

concrete anchors) are recommended.

2

G

• FOR DIRECT ATTACHMENT TO LOAD BEARING

CONCRETE ONLY! Concrete expansion anchors are
not intended for attachment to concrete ceilings
covered with a layer of plaster, drywall, or other
finishing material. If mounting to concrete ceiling
covered with plaster / drywall is unavoidable, plaster /
drywall must be counterbored as shown below.

WARNING

F

G

CONCRETE CEILING

concrete
anchor

Drill hole and insert anchor

Place ceiling plate over anchor and secure with screw

After repeating step one tighten all fasteners

• Tighten wood screws so that wall plate is firmly

attached, but do not overtighten. Overtightening can
damage the screws, greatly reducing their holding
power.

• Never tighten in excess of 80 in • lb (9 N.M.).

• Make sure that mounting screws are anchored into the

center of the studs. The use of an "edge to edge" stud
finder is highly recommended.

WARNING

• When installing wall mounts on concrete, verify that you have a minimum of 1 5/8" of actual concrete surface in the 1/

4" diameter hole to be used for the concrete anchors. Do not drill into mortar joints! Concrete must meet ASTM C-90
specifications.

• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.

• Make sure that the supporting surface will safely support the combined load of the equipment and all attached hard-

ware and components.

• Never exceed the Maximum Load Capacity of 50 lb (22.7 kg).

WARNING

Summary of Contents for NP01UCM

Page 1: ...w on the ball and socket mount This may cause the image to be unaligned when you let go Applications FlushMount page 7 ExtensionColumn page 8 Installations To Wood Joist Finished Ceilings Exposed Wood...

Page 2: ...NEC MT860 NEC LT84 NEC MT1060 NEC LT150 NEC MT1060R NEC LT150z NEC MT1065 NEC LT75 NEC Multisync LT245 NEC LT75z NEC NP1000 NEC LT85 NEC NP2000 NEC LT154 NEC V37 NEC LT155 NEC LT380 NEC LT156 NEC VT4...

Page 3: ...x head wood screw 2 5S1 015 C04 G ceiling plate 1 580 4042 H 25 ID x 56 OD x 26 spacer 2 590 2071 I extension column connector with cord management 1 580 4025 J 10 32 x 3 8 socket pin screw 2 520 2084...

Page 4: ...sample illustrated below Attach adapter plate L to projector using one screw M N O or P for each channel as shown below Tighten all screws while keeping the center of gravity Be sure that adapter plat...

Page 5: ...etween ceiling plate G and ceiling Installation To Wood Joist Finished Ceilings Exposed Wood Joists or Wood Beam Ceilings WOOD JOIST CEILING F F G H H Tighten wood screws F so that wall plate G is fir...

Page 6: ...l If mounting to concrete ceiling covered with plaster drywall is unavoidable plaster drywall must be counterbored as shown below WARNING F G CONCRETECEILING concrete anchor Drill hole and insert anch...

Page 7: ...nd secure ball and socket mount A with a M5 x 10 mm socket pin screw C using security allen wrench B as shown in detail 1 Note Slotted set screw K is used to jam against the threads of the ball and so...

Page 8: ...using security allen wrench B See detail 5 Screw ball and socket mount A to extension column connector I Align slot in ball and socket mount A to one of the bottom holes in extension column connector...

Page 9: ...mount A into the adapter plate connection and twisting until the adapter plate will no longer turn about 75 The spring loaded captive screw should line up with a corresponding hole on the adapter pla...