![NEC NEAX IPS NWA-008869-001 Installation Manual Download Page 53](http://html1.mh-extra.com/html/nec/neax-ips-nwa-008869-001/neax-ips-nwa-008869-001_installation-manual_4274290053.webp)
CHAPTER 2 INSTALLATION
– 43 –
NWA-008869-001 Rev.1.0
atch2001.fm
Lamp Indications
LAMP
NAME
COLOR
FUNCTION
RUN
Green
Flashes at 120 IPM while this card is operating normally.
CRC
Red
Remains lit when detecting Cyclic Redundancy Checking (CRC)
errors.
PCM
Red
Remains lit when detecting PCM signal loss.
FRM
Red
Remains lit when detecting Frame Alignment signal loss.
RMT
Red
Remains lit when receiving Frame Alignment signal loss alarm from a
distant office.
AIS
Red
Remains lit when a pattern of consecutive “1” is received. The distant
office transmits this signal for a loopback test.
BL
Red
B channel status
ON
: More than 10 channels are busy
OFF
: All channels are idle
Flash (60 IPM)
: Only one channel is busy
Flash (120 IPM) : 2 through 10 channels are busy
INSTALLATION PROCEDURE
Summary of Contents for NEAX IPS NWA-008869-001
Page 1: ...NWA 008869 001 ISSUE 1 In Skin Router Installation Guide JUNE 2005 NEC Corporation...
Page 6: ...THIS PAGE LEFT BLANK INTENTIONALLY...
Page 22: ...12 NWA 008869 001 Rev 1 0 atch1001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Page 80: ...70 NWA 008869 001 Rev 1 0 atch2001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Page 100: ...90 NWA 008869 001 Rev 1 0 atch3001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Page 144: ...134 NWA 008869 001 Rev 1 0 atch5001 fm THIS PAGE LEFT BLANK INTENTIONALLY...
Page 180: ...A4 NWA 008869 001 Rev 1 0 atapa001 fm THIS PAGE LEFT BLANK INTENTIONALLY...