CHAPTER 8
ND-70185 (E)
Page 194
Revision 3.0
EX- FCCS
Data Programming
1.
To Log-in to All Nodes in EX-FCCS Network
Perform the following data programming at each NCN of all the Fusion Groups.
STEP 1:
AFUGN
Assign EX-FCCS Fusion Group data. Designate Self FUG Number, connection FUG Number and
Fusion Point Code of the NCN within each FUG. Either of the FUGs assigned as the Center FUG by
clicking the “CENTER” check box.
STEP 2:
AEXFN
Assign the CCH Selection Data by designating all the Fusion Point Code (FPC) and the Point Code
(PC) in the connected Fusion Group.
Note:
Confirm whether the Centralized MAT can log in to each node here. Reexamine the assigned data so far if
log in can’t be executed. There may be some error in data setting.
2.
To Access EX-FCCS Trunk via EX-FCCS Telephone Number
Assign the data at the NCN of each Fusion Group. Abbreviate Digit Code (ADC) data must be set by AEADN
command at each NCN of all the FUGs. Assign the EX-FCCS Telephone Number data by using AELGN com-
mand at the NCN of the Center FUG only.
AEADN: Assign the Abbreviate Digit Code (ADC) for connection Fusion Group. Enter the FUG Number as-
signed by AFUGN command, TN, and ADC to be assigned.
AELGN: Telephone Numbers must be assigned for all the station within the network uniquely. Use AELGN
command to allocate EX-FCCS Telephone Number. FUG data must be assigned previously by
AFUGN command to activate this command.
Only readout function can be used by this command in case both the Self FUG Number and the Con-
nection FUG Number are assigned, if the Self FUG is not the Center FUG.
Note:
Check whether the trunk originating call via CCIS can be executed by dialing EX-FCCS Telephone Number
here. Reexamine the assigned data if the call cannot be connected. There may be some error in data setting
up to now.
<NCN of each FUG>