ND-70185 (E)
CHAPTER 5
Page 95
Revision 3.0
DATA PROGRAMMING
Assignment of FCH Related Data
•
Connection Link (for Data)
C_RT: 11
TCL=4
LSG=13
STEP 3:
ACTK
Assign the Connection Trunk data for B-ch and D-ch.
Example:
(When using 512kbps (8ch) TS as Connection link)
•
Connection trunk (B-ch)
C_RT: 10
TK: 1-664
CLENS: LEN for the SDT
•
Connection Link (D-ch)
C_RT: 11
TK: 1-8
CLENS: LEN for the FCH
C_RT: 11
TK: 9-16
CLENS: LEN for the SDT
Note:
Set the switch on the FCH card depending on the transmission speed.
See “
CHAPTER 4 INSTALLATION
” for more information on switch settings.
STEP 4:
AFCH
Assign the FCCH number for each FCCH.
FCHN: 2 (FCCH number)
FCHEN: LEN of FCCH
STEP 5:
AFPC
Assign the FCCS routing data.
FPC: 1 (FPC of the adjacent node)
FCCH: 1 (with FCCH)
CRT: 10
FCHN: 2
STEP 6:
ACAN
Assign the CIC number to the connection trunk.
FPC: 1
FCIC: 1-664
CLENS: LEN of the connection trunk
STEP 7:
AFRT
Assign the FCCH Controlled Connection Route data.
FCHN: 2
CRT: 10