124
(2) OS cannot be installed (No virtual disks found in the system).
□
Have virtual disks been created?
Create virtual disks using WebBIOS.
□
Has the BIOS SETUP of the server been changed?
The BIOS SETUP of the server needs to be set when [Load Setup Defaults] was executed or
the disk array controller has been installed for the first time. Run BIOS SETUP, enable
Option ROM Scan for the slot with the disk array controller, disable the parameters for the
onboard SCSI controller, and check the boot priority of the destination device. See "1. Before
Using WebBIOS" in Chapter 5 for details.
(3) OS cannot be booted.
□
Is the boot priority of the destination device low?
Check the boot priority of the disk array controller in the [Boot] menu of BIOS SETUP of the
server. The disk array controller is displayed as "PCI SCSI: (Bus XX Dev XX) PCI RAID Ad"
if the virtual disk has been recognized.
□
Is the disk array controller correctly inserted into the Mezzanine card slot?
If not, install the disk array controller correctly.
□
Is the disk array controller inserted into a Mezzanine card slot for which some installation
limitations are imposed?
Check the limitations imposed on the installation of the disk array controller and insert the
controller into the correct slot.
If the OS is not recognized despite the above actions, the disk array controller may be defective.
Contact your service representative.
□
Are the HDD
‟s inserted correctly?
Install the HDD
‟s in the slots correctly.
□
Are the internal cables connected to the disk array controller, HDD
‟s, and/or backplane board
correctly?
Connect the cables correctly.
If the OS is not recognized despite the above actions, one or more HDD
‟s may be defective.
Contact your service representative.
(4) MSM log
The following message is recorded in MSM log or Windows event log (application) every time the
MSM (MegaRAID Storage Manager) is started.
MSM log
Controller ID:x BBU disables; changing WB logical drives to WB.
Windows event log (application)
Source:
MR_MONITOR
Type:
Warning
Event ID:
195
Description:
Controller ID:x BBU disables; changing WB logical drives to WT.
The disk array controller does not support battery backup. If the message shown above
appears on POST, press
D
to disable this warning.
Summary of Contents for N8403-019
Page 14: ...xii Express5800 Serial Attached SCSI SAS HDD HDD LAN SCSI VCCI A...
Page 22: ...2 1 2 HDD HDD 3 1 1 MSM...
Page 24: ...4 3 SAS I F 1 1 2 RAID 1 300MB 300MB 256MB DDR 1 2 SAS HDD 1 2 RAID 0 1 ESMPRO HDD PCI...
Page 25: ...5 4 4 1 1 Port 0 1 N...
Page 26: ...6 4 2 SAS...
Page 27: ...7 4 3 4 4...
Page 31: ...11 2 3 RAID1 1 HDD 1 HDD 1 HDD HDD HDD HDD Disk 0 Disk 1 1 2 1 2...
Page 36: ...16 4 1 4 2 HDD 5 1 Web BIOS 5 2 1Web BIOS 5 3 5 4 1 Check Consistency...
Page 37: ...17 1 1 1 HDD HDD HDD LAN SCSI 1 OS 2 POWER 3 4...
Page 38: ...18 2 N8400 029 030 Express5800 120Bb 6 PCI 1 5...
Page 39: ...19 6 7 2 2 120Bb 6...
Page 40: ...20 8 1 2 3...
Page 41: ...21 4 5...
Page 42: ...22 6 7...
Page 43: ...23 9...
Page 44: ...24 10...
Page 77: ...57 Home WebBIOS Scan Devices Consistency Check Rebuild WebBIOS...
Page 78: ...58 6 1 NEC NEC 2 2 1 HDD EXPRESSBUILDER 2 2 HDD HDD 3 1 1 MSM...
Page 106: ...86 7 Install the rear cover...
Page 111: ...91 When the adapter is selected in Adapter Selection the WebBIOS top menu appears...
Page 113: ...93 Click Next to see the detailed settings of this controller...
Page 124: ...104 Custom Configuration Use this menu to define several physical drives PD as a disk group DG...