![background image](http://html1.mh-extra.com/html/nec/n8100-2834f/n8100-2834f_maintenance-manual_4540074081.webp)
2. RAID System Configuration
Express5800/R120h-1M, R120h-2M (3rd-Gen) Maintenance Guide
81
Chapter 2 Useful Features
2.3
Menu Tree of HPE Smart Array S100i Utility
Menu Default
Value
Descriptions
Controller Information
Controller
HPE Smart
Array S100 SR
Gen10
Controller Information
Device ID
PCIe device ID
PCI Slot number
PCIe Slot number
Firmware version
Firmware version
Firmware release date
Firmware release date
UEFI Driver version
UEFI Driver version
UEFI Driver release date
UEFI Driver release date
Configuration Summary
Summary of disk and array information
Configure Controller Settings
> Modify Controller Settings
Rebuild Priority
High
Priority at which the logical drives are
rebuilt from the failed state. It can be low,
medium, medium high or high.
Surface Scan Analysis Priority
3
0:Disable. 31:High. 1-31:Idle(with delay).
Modifies the amount of delay/idle time of
the controller before the surface scan
analysis is resumed again.
Current Parallel Surface Scan Count
1
Set the maximum number of surface scans
that can run at the same time. Setting 1
disables the feature.
Spare Activation Mode
Failure Spare
Activation
Option to change between the failure or
predictive spare activation modes.
Physical Drive Write Cache State
Disabled
Option for enabling the write cache on the
physical drives.
> Advanced Controller Settings
Physical Drive Request Elevator Sort
Enabled
Enable or disable the physical drive cache
write elevator sort algorithm.
Monitor and Performance Analysis Delay 60
0-1440: input range. 60: Default.
Set the monitor and performance analysis
delay.
HDD Flexible Latency Optimization
Disabled
Enable or Disable the flexible Latency
scheduler to limit the high latency request
from the HDDs.
Summary of Contents for N8100-2834F