BASIC OPERATION
Static Convergence Adjustment
Adjust for the red and blue CRTs to place their pattern on top of the
green test pattern (center only).
NOTE:
The static convergence adjustment should be performed for
R and B CRT. Carry out the adjustment after displaying an active
image for 20 minutes or more.
Proceed as follows:
1
Press the OPERATE button.
• The “OPERATE” menu is displayed.
2
Use the CURSOR
or
button to highlight the “6/STATIC”
line and then press ENTER to display the STATIC adjustment
screen. You can also select the STATIC adjustment screen
directly by pressing the INPUT “6” button , or by pressing the
STATIC button on the remote control.
• The CROSS-HAIR test pattern will be automatically displayed.
3
Press the R or B button to display the pattern to be aligned with
the Green pattern (as used a reference color).
• You can turn on or off each CRT beam (R and B) separately.
4
Hold down the CTL button then select the CRT you wish to
adjust with the R and B buttons.
5
Align the center of the Red or the Blue pattern with the center of
the Green pattern using the CURSOR buttons.
• The CURSOR
or
button moves the pattern right or left.
The CURSOR
or
button moves the pattern up or down.
6
Repeat steps
3
to
5
for the other CRTs if necessary.
7
To end this adjustment, press the END button.
• Whenever the END button is pressed, the screen changes in this
order:
“OPERATE” menu
→
Source screen
– O P E R A T E –
1 / P I C T U R E
2 / P O S I T I O N
3 / S O U N D
4 / I N P U T S E L E C T
5 / S O U R C E I N F O
6 / S T A T I C
7 / C L O S E D C A P T I O N
8 / T I M E R
+ 1 0 %
– 1 0 %
V
H
C O N V E R G E N C E
– S T A T I C –
C R T – R –
Red or Blue
Green