8.1
Insulation Resistance Test
An insulation resistance should be measured under the conditions specified below, in order to confirm
that the requirements of the judgment standard are met.
1) Measuring conditions
Measuring instrument : 500V DC MEGOHM Meter
Testing point : Between the power circuit block and the exposed metallic block
(D-SUB connector)
Measured value readout : A test voltage should be applied for one minute and the resistance
value should be read out thereafter.
2) Judgment standard:
The resistance of the insulation between the power terminal and the ground contact is more
than 10M ohms while withstanding a voltage of 500Vdc.
8.2
Dielectric Strength Test
To confirm the freedom from insulation breakdown, testing should be carried out under the conditions
specified below.
1) Measuring conditions
Measuring instrument: Dielectric strength tester (The specified voltage should be maintained in the
state that a current of 10mA is carried.)
Testing point: Between the electrical circuit block and the exposed metallic block (D-SUB
connector)
Note : The electrical circuit block should mean the power input block (primary side). Testing should
be carried out under the condition that both poles of the power plug are short-circuited. (Where
a 3-core cord is used, the two poles other than the
ground
terminal should be short-circuited.)
2) Judgment standard
There is no breakdown of the insulators or short circuits when applying an alternating potential of
1000Vac for a duration of 1(one) minute or 1500Vac for a duration of 2(two) second at 50Hz
between the metallic chassis and the input power supply active and neutral terminals connected
together.
●
●
●
●
●
Summary of Contents for MultiSync 20WGX2 Series
Page 5: ...MultiSync 20WGX2 User s Manual ...
Page 45: ...4 8 Page 6 Each Color Temperature Data Adjustment needed Page 5 LCD panel type ...
Page 116: ...8 1 REPLACEMENT PARTS LIST TABLE OF CONTENTS Page Model 20WGX2 B For Europe 8 2 ...
Page 140: ...11 1 PACKING SPECIFICATION TABLE OF CONTENTS Page B Version 11 2 ...
Page 141: ...11 2 ...
Page 143: ...12 1 Revision History Revision Revision New Issue 1st Edition 2006 03 ...