5-6
2.2 Power Supply
(*1) The power consumption should meet to Energy Star Ver 4.0 Tier 2.
Condition : Input Signal :
Native resolution, maximum freq
Image pattern:
Worst condition
Brightness:
175cd/m
2
or minimum
USB Upstream:
Connected
USD Downstream: No load.
Criteria: Under 50W.
kk+Inlet connector type:
3 polarity, 10A 250V 65degC
VDE, UL CSA approved CEE input connector.
EN60320 Class I standard compliant
Pin
Name
Definition
1
L
Live
2
N
Neutral
3
FG
GND (
Ground
)
3
1
2
Input Voltage
AC100 - 240V +/- 10%
Input Current (*1)
1.0 A@AC100V / 0.52 A@AC240V
Frequency
50 / 60 Hz +/-3Hz
Power Consumption
84 W (Max) with USB no load condition (*1)
AC Leakage current
< 3.5mA (AC120V/240V)
< 0.2mA (at AC100V with 2pin AC cable without GND)
Inrush current (cold start) < 30Arms