English-9
English
Caution
For connection to the DVI input(s), make sure to use a DVI Dual Link cable.
Dual-link
Single-link
•
Precautions to display two 3MP screens from one computer (Figure D):
A display controller model, which has two outputs of the same signal type (either DVI + DVI or Displ DisplayPort)
is recommended. Using two outputs with different signal types, (i.e. DVI + DisplayPort) of the same display controller is
not recommended. Doing so may result in slight differences of luminance and color between left and right screen and/or a
frame skip*.
Using outputs from different display controllers may cause a frame skip, even if the outputs are of the same signal type.
Please also refer to the GammaCompMD QA user manual for correct setup for dual screen operation.
•
Precautions to display two 3MP screens from two computers (Figure E):
This confi guration is not recommended, as it may cause a frame skip*. In addition, mixed connection of different signal types
(DVI + DisplayPort) may result in slight differences of luminance and color between left and right screen, depending on the
display controller models used in the two computers.
Note:
This confi guration is not supported by the NEC GammaCompMD QA calibration software.
Two 3MP screens from
1 computer
Two 3MP screens from
two computers
Figure D
Figure E
•
Precautions to display two 3MP screens or screens with the resolution other than 6MP:
< Examples >
XGA
3MP screen
XGA
VGA screen
XGA screen
Some resolutions other than two 3MP screens or one 6MP screen are supported, but their display performance is not
guaranteed. Doing so may result in slight differences of luminance and color between left and right screen or a frame skip*.
Note:
Mixed resolution confi gurations are not supported by the NEC GammaCompMD QA calibration software.
* Frame skip:
Difference of image display between left and right screens caused by fast movement of a cursor or window or by video display.