68
7.43.
“
CURTEMP_MAIN
”
Control procedure
7.43.1. Current main Temperature state read
CMD
Data1
Data2
Data3
Data4
Command
(0xF4)
Target
(0x89)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x37)
Command (0xF4) : Start bit
Target (0x89) : Get bit
Monitor ID (0x00) : Default value -> 0x00
CMD(0xFE) : command data
Parameter (0x37) :
‘
CURTEMP_MAIN
’
parameter
CMD
Data1
Command
(0xF1)
Value
Command (0xF1) : Start send bit
Value : Current Temperature getting value
7.44.
“
CURTEMP_AUX
”
Control procedure
7.44.1. Current aux Temperature state read
CMD
Data1
Data2
Data3
Data4
Command
(0xF4)
Target
(0x89)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x38)
Command (0xF4) : Start bit
Target (0x89) : Get bit
Monitor ID (0x00) : Default value -> 0x00
CMD(0xFE) : command data
Parameter (0x38) :
‘
CURTEMP_AUX
’
parameter
CMD
Data1
Command
(0xF1)
Value
Command (0xF1) : Start send bit
Value : Current Temperature getting value