7.41.
“
MIN_ILLUMINANCE
”
Control procedure
7.41.1. MIN_ILLUMINANCE Control
CMD
Data1
Data2
Data3
Data4
Data5
Command
(0xF5)
Target
(0x88)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x34)
Value
Command (0xF5) : Start bit
Target (0x88) : Set bit
Monitor ID (0x00) : Default value -> 0x00
CMD (0xFE) : command data
Parameter(0x34) :
‘
MIN_ILLUMINANCE
’
parameter
Value: 0 ~ 200 (range)
7.41.2. Current MIN_ILLUMINANCE state read
CMD
Data1
Data2
Data3
Data4
Command
(0xF4)
Target
(0x89)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x34)
Command (0xF4) : Start bit
Target (0x89) : Get bit
Monitor ID (0x00) : Default value -> 0x00
CMD(0xFE) : command data
Parameter (0x34) :
‘
MIN_ILLUMINANCE
’
parameter
CMD
Data1
Command
(0xF1)
Value
Command (0xF1) : Start send bit
Value : Current MIN_ILLUMINANCE getting value
0 ~ 200 (range)