38
7.15.
“
SCALEMODE
”
Control procedure
7.15.1. Current Scale mode Control
CMD
Data1
Data2
Data3
Data4
Data5
Command
(0xF5)
Target
(0x88)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x0E)
Value
Command (0xF5) : Start bit
Target (0x88) : Set bit
Monitor ID (0x00) : Default value -> 0x00
CMD (0xFE) : command data
Parameter(0x0E) :
‘
SCALEMODE
’
parameter
Value : Data value
1 : Full Scn
2 : Panorama
3 : Zoom1
4 : Zoom2
5 : 4:3
6 : 14:9
7 : 4:3
8 : Full Scn
9 : 1:1
7.15.2. Current Scale mode state read
CMD
Data1
Data2
Data3
Data4
Command
(0xF4)
Target
(0x89)
Monitor ID
(0x00)
CMD
(0xFE)
Parameter
(0x0E)
Command (0xF4) : Start bit
Target (0x89) : Get bit
Monitor ID (0x00) : Default value -> 0x00
CMD(0xFE) : command data
Parameter (0x0E) :
‘
SCALEMODE
’
parameter
CMD
Data1
Command
(0xF1)
Value
Command (0xF1) : Start send bit
Value : Current Source getting value
1 : Full Scn
2 : Panorama
3 : Zoom1
4 : Zoom2
5 : 4:3
6 : 14:9
7 : 4:3
8 : Full Scn
9 : 1:1
AV , S-video , Component mode
PC, Digital video mode
AV , S-video , Component mode
PC, Digital video mode