10) When the [WRITE EDID] button is pressed, writing of the EDID data only is carried out. Upon the
completion of correct writing, a display of [EDID Monitor Write OK] is presented in the column of
[STATUS].
1.4.2 DVI-D (Digital) EDID Data Write
1) Connect the EDID data writing unit with jigs, etc. (Refer to a DVI connector connection figure)
2) The "BACK" button is pushed twice and the [MODEL SELECT] screen is displayed. Cursor is united and
double-clicked to [LCD1700NX-DIGITAL].
3) 6) to 10) is carried out in the procedure of the 1.4.1 " D-Sub (Analog) EDID Data Write".