17
Chapter 1
Overview
Preliminary User’s Manual U16345EE1V0UM00
1.7 Connection between IE-V850ES-G1 and IE-703242-G1-EM1
The procedure for connecting the IE-V850ES-G1 and the IE-703242-G1-EM1 is shown below.
1.
Disconnect the power from IE-V850-ES-G1.
2.
Remove the cover of the IE-V850ES-G1.
3.
Make jumper settings on main board of IE-V850ES-G1 as described in 2.3 Jumper
4.
Place the IE-703242-G1-EM1 over the main board of IE-V850ES-G1 so that the board connectors
are in the correct position.
5.
Press IE-703242-G1-EM1 carefully so that the connection to the main board is secured.
6.
Fix the IE-703242-G1-EM1 to the main board using the screws delivered with the board.
7.
If the tool is used with a target board for emulation connect the probe adapter (SWEX-100SD1) to
the appropriate socket (SO2) of IE-703242-G1-EM1.
8.
Close the cover of the IE-V850ES-G1.
9.
Reconnect the power to the IE-V850ES-G1.
10. If the tool is used with a target board for emulation connect the target socket probe adapter to the
emulation target (emulation target powered off).
Cautions: 1. Connect carefully so as not to break or bend connector pins.
2. Take care to match pin 1 when connecting the probe adapter to the probe socket
of IE-703242-G1-EM1.
1.8 Power up sequence
Power on the emulation system first, then power on the target system.
Summary of Contents for IE-703242-G1-EM1
Page 6: ...6 Preliminary User s Manual U16345EE1V0UM00 ...
Page 8: ...8 Preliminary User s Manual U16345EE1V0UM00 ...
Page 10: ...10 Preliminary User s Manual U16345EE1V0UM00 ...
Page 18: ...18 Preliminary User s Manual U16345EE1V0UM00 MEMO ...
Page 28: ...28 Preliminary User s Manual U16345EE1V0UM00 MEMO ...
Page 30: ...30 Preliminary User s Manual U16345EE1V0UM00 MEMO ...
Page 36: ...36 Preliminary User s Manual U16345EE1V0UM00 MEMO ...
Page 40: ...40 Preliminary User s Manual U16345EE1V0UM00 ...
Page 42: ......