Switch Settings
(1) S1 setting
Set as follows in accordance with the target device.
Figure 3-2. S1 Setting
Target Device
S1-1
S1-2
S1-3
µ
PD178F098
OFF
OFF
OFF
RESERVED
OFF
ON
OFF
µ
PD178076, 178078,
178096, 178098
OFF
ON
ON
RESERVED
ON
OFF
OFF
RESERVED
ON
OFF
ON
RESERVED
ON
ON
OFF
RESERVED
ON
ON
ON
Remark The above figure shows the position at factory shipment.
(2) S2 and S3 settings
S2 and S3 switch the capacitor connection for the regulator.
"I" side:
Connect to the 0.1
µ
F in the ICE
"U" side: Connect to the capacitor in the target system
Figure 3-3. S2 and S3 Settings
Remark
The above figure shows the position at factory shipment.
1
2
3
OFF
ON
OFF
I
OSCREG (S2)
U
I
CPUREG (S3)
U