Response: At the time of a success
23H 9BH 01H xxH 07H DATA01 to DATA07 CKS
(*1) (*2) (*3)
Data Portion Contents
-----------------------------------------------------------------
DATA01 same values as DATA01 of the command
DATA02 same values as DATA02 of the command
DATA03 same values as DATA03 of the command
DATA04 to 07 Acquired information
Response: At the time of a failure
A3H 9BH 01H xxH 02H DATA01 DATA02 CKS
(*1) (*2) (*4) (*3)
Supplement:
* In case of acquiring lamp's use of hours
03H 9BH 00H 00H 03H 00H 00H 01H CKS
Example of acquisition
DATA04 DATA05 DATA06 DATA07 : lamp's use of hours
50H 46H 00H 00H : 18000 seconds
Lamp Usage = 18000 / 3600 = 5 hour
(!1) X = 100 - ((Lamp Use Prohibited Time * 100) / Lamp Use Warning Starting Time)
Example) The case of Lamp Use Prohibited Time 2100[H] A
Lamp Use Warning Starting Time 2000[H] Model.
X = 100 - ((2100 * 100) / 2000) = -5[%]
(!2) Lamp Hour Meter
This is the timer for normal lamp mode conversion.
(!3) Lamp usage time
This is the lamp total usage. It is displayed in the projector's menu.
(!4) This setting is ignored, if the Item's unit is not time.
(!5) NP4000/4001, NP4100/4100W : This function is not supported.
038. LAMP MODE REQUEST
**********************************************************************
Function:
This command acquires the setting of the lamp mode of projector.
Command:
03H B0H 00H 00H 01H 07H BBH
Response: At the time of a success
23H B0H 01H xxH 02H DATA01 DATA02 CKS
(*1) (*2) (*3)
Data Portion Contents
-----------------------------------------------------------------
DATA01 07H fixed
DATA02 Setting Value
00H : Normal
01H : Eco
Response: At the time of a failure
A3H B0H 01H xxH 02H DATA01 DATA02 CKS
(*1) (*2) (*4) (*3)