006. RUNNING SENSE
**********************************************************************
Function:
This command acquires the operation mode of the projector.
Command:
00H 81H 00H 00H 00H 81H
Response: At the time of a success
20H 81H 01H xxH 01H DATA01 CKS
(*1) (*2) (*3)
Data Portion Contents
-------------------------------------------------------------------
DATA01 Status of operation
Bit 7: Power On/Off processing
0 = No execution (Normal condition)
1 = During execution
Bit 6: Selecting signal processing
0 = No execution (Normal condition)
1 = During execution
Bit 5: Cooling processing
0 = No execution (Normal condition)
1 = During execution
Bit 4: External control mode
0 = OFF
1 = ON
Bit 3: No Power-Off period
0 = Power-Off Possible (Normal condition)
1 = Power-Off Impossible
Bit 2: Reserved
Bit 1: Projector status
0 = Idling
1 = Power On
Bit 0: Reserved
Response: At the time of a failure
A0H 81H 01H xxH 02H DATA1H DATA02 CKS
(*1) (*2)
(*4) (*3)
007. COMMON DATA REQUEST
**********************************************************************
Function:
This command acquires all of the detailed conditions of the projector.
Command:
00H C0H 00H 00H 00H C0H