Monitoring the ft Server
Maintenance
Select the
Maintenance
folder. Data Viewer displays the PCI module
Maintenance
screen.
Bring Up/Bring Down:
Using the
Maintenance
screen you can bring the
selected PCI module up or down. When a module is brought down (stopped),
firmware in this module may be updated or this module can safely be removed
from your server. If one PCI module is down or removed, the system continues
normal operation using the companion PCI module.
Note:
In the following procedure PCI module 1 will be
brought down.
Procedure:
1.
In Data Viewer, select the General folder of PCI module 1. The General
screen displays.
2.
Check the current state of the Status display located at the bottom of this
screen. A green Status display indicates the PCI module is up; a gray Status
display indicates the PCI module is down.
3.
Switch to PCI 1 module
Maintenance
folder and click on
the Bring Down
button to bring down PCI module 1.
4.
Select the PCI
General
folder and verify the PCI module is down by
checking the Status display. The PCI stop operation is reported as an alert by
ESMPRO.
5.
To bring PCI module up, perform Steps 1 and 2 above, then switch to
PCI 1 module
Maintenance
folder and click on
the Bring Up
button to bring
up PCI module 1.