4-8
Monitoring the ft Server
Maintenance
Select the
Maintenance
folder. Data Viewer displays the CPU module
Maintenance
screen.
Bring Up/Bring Down:
Using the
Maintenance
screen you can bring the
selected CPU module up or down. When a module is brought down (stopped),
firmware in this module may be updated or this module can safely be removed
from your server. If one CPU module is down or removed, the system continues
normal operation using the companion CPU module.
Note:
In the following procedure CPU module 1 will be
brought down.
Procedure:
1.
In Data Viewer, select the General folder of CPU module 1. The General
screen displays.
2.
Check the current state of the Status display located at the bottom of this
screen. A green Status display indicates the CPU module is up; a gray Status
display indicates the CPU module is already down.
3.
Switch to CPU 1 module
Maintenance
folder and click on
the Bring Down
button to bring down CPU module 1.
4.
Select the
General
folder and verify the CPU module is down by checking
the Status display. The CPU stop operation is reported as an alert by
ESMPRO.
5.
To bring CPU module up, perform Steps 1 and 2 above, then switch to
CPU 1 module
Maintenance
folder and click on
the Bring Up
button to
bring up CPU module 1.