This screen displays and sets the various functions of BMC.
Item
Description
Default Value
SEL SEL
setting
Behavior when SEL
repository is full
Select the Behavior when SEL repository is full. *1
Stop logging SEL
: SEL is not recorded any more.
Clear all SEL
: Delete all SEL and record SEL newly.
Overwrite oldest SEL
: Old SEL is overwritten with new SEL.
Stop logging SEL
Power Restore Delay
Power Restore Delay setting
AC-Link
Select the AC-Link setting.
Stay Off
: DC is not turned on.
Last State
: It becomes the same as time when AC was turned off.
Power On
: DC on always.
Last State
Delay Time
Set the value or specify the Random. The range is from
"Minimum value" to "600"[Sec], *2
Minimum value
PEF PEF
setting
Platform Event Filter
Select Enable/Disable of Platform Event Filter. *3
Enable
Management Software