BMC Configuration User’s Guide
Item
Description
Default Value *1
Basic Configuration
Basic Configuration setting
POST Error Pause
Select Enable/Disable of POST Error Pause.
Enable
Memory Error *2
Select Halt/Boot of Memory Error.
Boot
CLI Setup *2
Select Enable/Disable of CLI Setup.
Disable
Standby Power Save *2
Select Enable/Disable of Standby Power Save.
Disable
Serial Port A Configuration
Serial Port A Configuration setting
Serial Port A
Select Enable/Disable of Serial Port A.
Enable
Serial A Base I/O
Select Base I/O Address of Serial Port A. It
must be different from Serial Port B.
3F8h
Serial A Interrupt
Select IRQ of Serial Port A. It must be different
from Serial Port B.
IRQ 4
Serial Port B Configuration
Serial Port B Configuration setting
Serial Port B
Select Enable/Disable of Serial Port B.
Enable
Serial B Base I/O
Select Base I/O Address of Serial Port B. It
must be different from Serial Port A.
2F8h
Serial B Interrupt
Select IRQ of Serial Port B. It must be different
from Serial Port A.
IRQ 3
Console Redirection Configuration
Console Redirection Configuration setting
BIOS Redirection Port
Select BIOS Redirection Port. You can not
select “Disable” Port.
Disabled
Terminal Type
Select Terminal Type.
VT-100+
Baud Rate
Select Baud Rate.
115200
Data Bits
Select Data Bits.
8
Stop Bits
Select Stop Bits
1
Parity Select
Parity.
None
Flow Control
Select Flow Control.
Hardware
RTS/CTS
Continue C.R. after POST
Select Enable/Disable of Continue Console
Redirection after POST.
Enable
*1: The value might be different according to the system.
*2: It is not displayed when the system does not support this function.
CHECK: