4-24 Configuring Your Server
Option
Parameter
Description
Your Setting
Power on Delay
Time
[0] - 255
Specify the DC power on delay
time within the range between 0
and 255 seconds. The time
specified is valid when "Power On"
or "Last State" is specified for AC
LINK.
Platform Event
Filtering
Disabled
[Enabled]
This item becomes meaningless
when the notification feature of
EXPRESSSCOPE Engine is
enabled.
[ ]: Factory-set
The table below shows the operation when the AC power to the server is turn off once and then on
again, depending on the setting of "AC LINK."
Setting of AC LINK
System status before AC power off
Stay Off
Last State
Power On
Operating
Off
On
On
Aborting (DC power being off also)
Off
Off
On
Forced shutdown
Off
Off
On
* Press the power switch continuously for four seconds or longer. This forcibly turns off the power.
IMPORTANT:
To power on the server from the UPS (Uninterruptible Power
Supply), select [Server] - [AC Link] - [Power On].
If the server is connected to the UPS, set at least 10 seconds delay in
the power-on schedule.
Summary of Contents for Express 5800/120Eh
Page 16: ...x This page is intentionally left blank ...
Page 36: ...2 8 General Description Internal View SAS Model 1 2 4 5 1 6 7 8 3 2 3 1 5 2 10 9 ...
Page 52: ...2 24 General Description This page is intentionally left blank ...
Page 112: ...4 48 Configuring Your Server This page is intentionally left blank ...
Page 176: ...7 12 Maintenance This page is intentionally left blank ...
Page 338: ...E 24 Installing Windows Server 2003 This page is intentionally left blank ...
Page 342: ...F 4 Product Configuration Record Table This page is intentionally left blank ...