1. Specifications
Express5800/D120h User’s Guide
121
Chapter 4 Appendix
1.2
Module Enclosure
Product number
N8141-83F (Onboard Model)
N8141-92F (RAID Controller,SAS Controller
Model)
N8141-84F (Onboard Model)
N8141-93F (RAID Controller,SAS Controller
Model)
Number of server modules
that can be mounted
Up to four Express5800/D120h can be mounted : 1U server module
Chassis design
2U Rack mount type
External dimensions
(width x depth x height)
440.0mm x 820.0mm x 87.5mm (Rails/projections are excluded)
485.0mm x 820.0mm x 87.5mm (Rails/projections are included)
Weight (minimum *1 /
maximum *2)
22 kg / 39 kg (when four server modules are mounted)
Power Supply Unit
1300W (N8181-154)
2200W (N8181-155)
Power supply
Pre-installed
1300W/2200W 80 Plus® Platinum compliant (bipolar grounded outlet) (hot-plug available)
(Maximum: 2)
100 to 127/200 to 240 VAC ± 10% (1300-W power supply), 100 to 127/200 to 240 VAC ± 10%
(2200-W power supply),
50/60 Hz ± 3 Hz (The power cable must be selected.)
Redundant power supply
Supported (hot-plug available)
Redundant fan
Supported(hot-plug unavailable)
Temperature/Humidity
Operating: 5 to 35°C / 20
~
80%
Storage: -10 to 55°C/20 to 80% (No condensation either when operating or when stored)
Accessories
Installation and Handling Guide, Safety Precautions and Regulatory Notices, Rack rails,
EXPRESSBUILDER
*1 The minimum configuration for operation (module enclosure, 2x power supply unit)
*2 The maximum configuration (module enclosure, 4x server module (full), 2x power supply unit)
Product number
N8141-91F (Onboard Model)
N8141-94F (RAID Controller,SAS Controller Model)
Number of server modules
that can be mounted
Up to two Express5800/D120h can be mounted : 2U server module
Chassis design 2U Rack
mount type
2U Rack mount type
External dimensions
(width x depth x height)
440.0mm x 820.0mm x 87.5mm (Rails/projections are excluded)
485.0mm x 820.0mm x 87.5mm (Rails/projections are included)
Weight (minimum *1 /
maximum *2)
22kg / 35.4 kg (when four server modules are mounted)
Power Supply Unit
2200W (N8181-155)
Power supply
Pre-installed
2200W 80 Plus® Platinum compliant (bipolar grounded outlet) (hot-plug available) (Maximum: 2)
100 to 127/200 to 240 VAC ± 10% (2200-W power supply),
50/60 Hz ± 3 Hz (The power cable must be selected.)*3
Redundant power supply
Supported (hot-plug available)
Redundant fan
Supported(hot-plug unavailable)
Temperature/Humidity
Operating : 5 to 35°C *3 / 20 to 80%
Storage : -10 to 55°C/20 to 80% (No condensation either when operating or when stored)
Accessories
Installation and Handling Guide, Safety Precautions and Regulatory Notices, Rack rails,
EXPRESSBUILDER
*1 The minimum configuration for operation (module enclosure, 2x power supply unit)
*2 The maximum configuration (module enclosure, 2x server module (full), power supply unit)
*3 The upper limit of operating temperature is 35°C when the power supply unit (2200 W) is installed.