2. BIOS Setup Utility (SETUP)
Express5800/D120h User’s Guide
108
Chapter 3 Setup
2.4
Cases That Require Configuration
Only if a case applies to any of following cases, use SETUP to change a parameter which was configured as
factory setting. A list of SETUP parameters and factory settings are described in
Chapter 2 (1. System BIOS)
in "
Maintenance Guide
".
Category
Description
To be changed
Remark
Basic
Change date and time
Main
→
System Date
Main
→
System Time
Configurable on OS
On NumLock on power ON
Boot
→
Bootup Numlock State
→
ON
or
OFF
-
Off the function to display NEC
logo during POST
Boot
→
Quite Boot
→
Disabled
By pressing <Esc> key, prevent
the display of the logo.
Memory
Add or change DIMM
Chipset
→
Runtime Error Logging
→
Memory Error Enabling
→
Clear Error
Memory Even log on SMB
→
Enable
Enable
Clear Error Memory
Even log on SMB
, and restart
the system. It is automatically
Disabled
.
Display
Display the MAC address of the
onboard LAN2.
Advanced
→
PCI Subsystem Settings
→
Onboard LAN2 I/O ROM
→
Enabled
Set this to display the MAC
address of “
Main
→
LOM2
”.
* Default indicates all zero
MAC address of LOM2 when
Onboard LAN2 I/O ROM
is
set to
Disabled
.
Optional
board
Disable Option ROM Scan of
installed option board
Advanced
→
PCI Subsystem Settings
submenu
→
PCI Express Slot#xx I/O
ROM
→
Disabled
xx
is PCI slot number of the
installed option board
Optional
board
(GPGPU)
When GPGPU is implemented Set as follows.
Advanced
→
PCI Subsystem Settings
→
Above 4G Decoding
→
Enable
Advanced
→
PCI Subsystem Settings
→
PCI Express Slot#4 I/O ROM
→
Enable
Chipset
→
Common RefCode
Configuration
→
MMIO High Base
→
1T
Change BIOS setting before
implementing GPGPU.
Boot
Set the boot mode to UEFI
mode according to your OS.
Set as follows.
Step1:Boot – Boot Mode Select
→
UEFI
Step2:Advanced – CSM Configuration
–
CSM Support
→
Enabled
Step3:Boot option filter
→
UEFI only
Network
→
UEFI
Storage
→
UEFI
Video
→
UEFI
Other PCI devices
→
UEFI
Step4:Advanced – CSM Configuration
– CSM Support
→
Disabled
Step5:Advanced
→
PCI Subsystem
Setting
→
Onboard LAN1 I/O
ROM
→
Enable*
Step6:Advanced
→
PCI Subsystem
Setting
→
Onboard LAN2 I/O
ROM
→
Enable*
* If you do not use at UEFI mode, set the
setting of LAN1 I/O ROM and the LAN2
I/O ROM to
Disabled
.
●
Select UEFI mode for the following OS.
- Windows Server 2012 R2
- Windows Server 2016
- Red Hat Enterprise Linux 7.3
(x86_64)
- VMware ESXi 6
For details, see
Installation
Guide
.
Factory settings is set to
UEFI
.
For detail of the CSM menu,
see
chapter 2((9) CSM UEFI
Driver Configuration submenu
in 1.2.2 Advanced)
in
Maintenance Guide
.