Backing Up Site Data
DS2000 Hardware Manual
Section 5: Maintenance Options and SMDR
◆
5-1
5
Section 5: Maintenance
Options and SMDR
Backing Up Site Data
Backing Up Site Data
PC Card Data Base Compatibility
Software version 03.**.** databases are not compatible with any prior 02.**.** versions.
Backing Up Site Data with a PC Card
You can use PC Card P/N 85880 to back up and restore your site data. You cannot store data bases on PC
Card with Software P/N 80051-V03.**.**.
To use the PC Card to back up site data
:
1.
Insert the PC Card into the CPU.
2.
Be sure the CPU mode switch is set to
RUN
.
3.
Enter the programming mode.
ICM + #*#* + HOLD
4.
Dial
9906
+
HOLD
.
You see:
START?
To quit program 9906 instead, dial
N
+
HOLD
.
5.
Dial
Y
+
HOLD
.
You see:
9906: DATABASE NAME
6.
Enter a name for the database you want to save (up to 10 characters long).
Refer to Figure 5-2 Entering Names on page 5-3 if you need help when entering names.
Skip this step if you want to save data in an address that already has a name assigned.
7.
When you are done entering the name, press
HOLD
.
You see the name and date of the first database stored. If no data bases are stored, you see:
9906: DB00
(empty)
8.
The system assigns the name you entered in step 7 to the data base address you select below:
- Press
VOL
▲
or
VOL
▼
to scroll through the addresses.
There are 16 data base addresses (DB 00 to DB 15).
OR
- Skip this step to select the currently displayed data base.
Summary of Contents for DS2000 IntraMail
Page 6: ...Table of Contents iv Table of Contents DS2000 Hardware Manual...
Page 22: ...Power Supply Installation 1 16 Section 1 Installing the Cabinet DS2000 Hardware Manual...
Page 36: ...Connecting Blocks 2 14 Section 2 PCB Installation DS2000 Hardware Manual...
Page 74: ...Parts List 6 8 Section 6 Specifications and Parts DS2000 Hardware Manual...