System Preparation and Configuration
DS2000 Hardware Manual
Section 1: Installing the Cabinet
◆
1-7
1
DS2000 System Load Factor Calculations
Description
Qty
Load Type
5 VDC
40 VDC
Load
Total
Load
Total
CPU PCB
1
6
6
0
0
16DSTU PCB
3
20
4ASTU PCB
3
5
8ASTU PCB
5
8
4ATRU PCB
4
0
8ATRU PCB
8
0
T1 PCB
8
0
UltraMail PCB (FMS)
19
0
UltraMail 2000 PCB (VMS)
0
5
Telephones (Keysets and SLTs)
0
0
110-Button DSS Console
0
2
24-Button DSS Console
0
1
2-OPX Module
0
3
Item 1: Load Type Totals
(Cannot exceed Item 2: Power Supply Capacity.)
Item 2: Power Supply Capacity
If you have one power supply installed, the capacity is:
If you have two power supplies installed, the capacity is:
If you have three power supplies installed, the capacity is:
5 VDC = 40
5 VDC = 80
5 VDC = 120
40 VDC = 48
40 VDC = 80
40 VDC = 120
Notes:
•
A 4 slot cabinet can only have 1 power supply.
•
An 8 slot cabinet can have up to 3 power supplies. You cannot have more than two 16DSTU PCBs per power sup-
ply, regardless of System Load Factor calculations.
•
Exceeding the allowed Load Type Total (Item 1) will cause the system’s power supplies to automatically shut down
and/or cause erratic system operation.
•
Total DSS Consoles installed cannot exceed 4.
•
In a 4 slot cabinet, the total of all station, trunk, and UltraMail ports cannot exceed 64.
•
In an 8 slot cabinet, the total of all station, trunk, and UltraMail ports cannot exceed 112.
Summary of Contents for DS2000 IntraMail
Page 6: ...Table of Contents iv Table of Contents DS2000 Hardware Manual...
Page 22: ...Power Supply Installation 1 16 Section 1 Installing the Cabinet DS2000 Hardware Manual...
Page 36: ...Connecting Blocks 2 14 Section 2 PCB Installation DS2000 Hardware Manual...
Page 74: ...Parts List 6 8 Section 6 Specifications and Parts DS2000 Hardware Manual...