2805 - PMS Timers
Feature Cross Reference
Flexible Message Timing
Telephone Programming Instructions
To enter data for Program 2805 (PMS Timers):
1. Enter the programming mode.
2. 2805 + HOLD.
Timer No (1-3)?
3. Enter the number of the timer you want to program (1-3) + HOLD
Time:n
The previously programmed value displays.
4. Enter data (see the chart above) for the timer se HOLD
Retry Count:n
The previously programmed value displays.
5. Enter the Retry Count for the timer selected in step 3 above +
HOLD
Timer No (1-3)?
6. Repeat from step 3 to program another timer.
OR
HOLD to exit.
Timer
30
(30 mS)
Retry
Count
10
Timer
5-100
(5-100 mS)
Retry Count
0 (i.e. no retry) -20
PMS Message Time
This timer starts when the Message
Start character (STX) is received. If
the End of Message character (ETX)
is not received, the system has the
option of ignoring the message or
sending a Non-Acknowledge (NAK)
signal to the PMS to have the mes-
sage resent. (Program 2803, Item 4
must be set to ‘1’).
When messages are slowed by the
NVM, increase this time.
4
3-43
3. Programming the
Hotel/Motel Options
92000hmt06.QXD 4/24/01 10:12 AM Page 43