Nebula NRH-600B Instruction Manual Download Page 6

5

 

Turn the screws 4 x ST4*25 mm as far as these
stick out about 10 mm from the wall.

Hang up the hood. Check the secure fitting, the
horizontal position and tighten first the upper and
then the lower screws through the hood body.

Remove the protective foil from the ducts.

Put on the outer (lower) duct and fix
it laterally to the hood with the
screws 2 x ST4*8.

For the extraction mode:

For the extraction mode:

For the extraction mode:

For the extraction mode:

 

Attach a flexible extraction hose (not
supplied) with an inner diameter of
Ø120 mm onto the connecting piece.

Slide the inner (upper) duct along the
slide fixture into the outer (lower)
duct. Make sure that the inner duct is
aligned with the vents at the top.

Determine the extension length of the duct cover
by pulling up the inner duct or sliding back into the
outer duct.

Attach the mounting rail at the upper duct ending.
Drill mounting holes 2 x Ø8 mm and insert the
dowel pins. Use the screws 2 x ST4*25 mm to se-
cure the rail.

For the extraction mode:

For the extraction mode:

For the extraction mode:

For the extraction mode:    

Check the correct position of the flexible extrac-
tion hose and connect it with the extraction out-
let to the outside.

Pull the inner duct upwards and fasten the duct
cover laterally to the previously
mounted rail using the screws 2 x
ST4*10 mm.

Installing the activated carbon

Installing the activated carbon

Installing the activated carbon

Installing the activated carbon    filter for recirculation 

filter for recirculation 

filter for recirculation 

filter for recirculation 

mode

mode

mode

mode    

Remove the aluminum grease filter.

Place the carbon filter onto the air intake of the
extraction duct. Make sure that the mounting pins
on the extraction duct engage the mounting slots
of the carbon filter. Turn the filter clockwise until it
clicks into place.

Reinstall the aluminum grease filter.

Electrical connection

Electrical connection

Electrical connection

Electrical connection    

    WARNING:

WARNING:

WARNING:

WARNING:    

The installation to the mains supply must conform
to the local standards and regulations.

Improper connection may cause to an electric

electric

electric

electric

shock

shock

shock

shock!

Do not modify the appliance plug. If the plug does
not fit properly to the outlet, let install a proper
outlet by an authorized specialist.

The accessibility of the power plug must be en-
sured to disconnect the appliance from the power
supply in case of emergency.

Ensure that your mains power corresponds with
the specifications of the appliance. The specifica-
tions are printed on the rating label.

Connect the mains cable to a properly installed
and earthed wall outlet.

If the plug after installation is not accessible, a
corresponding disconnect device must be availa-
ble to meet the relevant safety regulations.

Startup / Operation

Startup / Operation

Startup / Operation

Startup / Operation    

Cooker hood 

Cooker hood 

Cooker hood 

Cooker hood     
The diameter of the pot and pan floors should be 
according to the size of the cooking zone. 

Summary of Contents for NRH-600B

Page 1: ...Cooker Hood Instruction Manual TGO R700 NRH 600B...

Page 2: ...liance is only to be used as described in the user manual Do not use the appliance for any other purpose Any other use is not intended and can result in damages or personal injuries Operate the applia...

Page 3: ...ctions that we give you in the chapter Installation ATTENTION ATTENTION ATTENTION ATTENTION Accessible parts of the appliance may become hot when used with cooking utensils Do not flamb under the cook...

Page 4: ...ice or by qualified person and with a cable of the same type Unpacking the Appliance Unpacking the Appliance Unpacking the Appliance Unpacking the Appliance Remove the appliance from its packaging Rem...

Page 5: ...cted air comply with the regulations of the relevant local authorities The hood has an upper air outlet to vent cooking odours to the outside The extracted air is normally vented vertically The extrac...

Page 6: ...activated carbon Installing the activated carbon filter for recirculation filter for recirculation filter for recirculation filter for recirculation mode mode mode mode Remove the aluminum grease fil...

Page 7: ...When disassembling the hood be sure that you first loosen the lower and then the upper screws For the recycling and recovery of resources give the appliance the lamps and the various filter to a commu...

Page 8: ...se heat Therefore clean the grease filter regularly We recommend cleaning the grease filter monthly Remove the aluminum grease filter by sliding back the lock in the handle recess push the filter down...

Page 9: ...Check the power level Appliance is not working efficiently Check the power level Is the kitchen properly ventilated Clean the grease filter At recirculation mode check the carbon filter Check the air...

Reviews: