background image

 

Volume-controlled mode

 

 

 

 

 

 

22 

 

 

 

 

GERMAN 

The 

OPTINEB

®

-ir

 ultrasonic nebuliser switches off after reaching a remaining 

quantity of approx. 0.5 ml automatically. 
En (=End) appears in the display. 
 
You can restart 

OPTINEB

®

-ir 

only after refilling approx. 2 ml of medication 

solution. 
The nebulization time may differ in length and results from the set ventilation 
parameters. 
 
 

NOTE 

The remaining quantity left in the medication cup depends on the selected 
program: 
P1  

– approx. 0.5–1.5 ml remaining quantity 

P2  

– approx. 0.5–1.5 ml remaining quantity 

P3/P4/P5/P6   – approx. 0.5 ml remaining quantity 

 
ATTENTION 

Please note the maximum fill level of the medication to be nebulized. This may 
not be greater than 7.5 ml to ensure continuous aerosol production. 

 
 
9.0  Use of the OPTINEB

®

-ir ultrasonic nebulizer with a non-invasive 

ventilation mask. 

Connect extension hose [

A20

] and mask [

A21

] with 

OPTINEB

®

-ir

 

 

 
 

WATSON LABORATORIES, INC. , IPR2017-01621, Ex. 1006, p. 22 of 33

Summary of Contents for OPTINEB-ir ON-100/2-2.4 MHz

Page 1: ...ic Nebuliser Operating Instructions Operating Instructions for Artificial Respiration ventilation for physicians and authorized clinic personnel for physicians and authorized clinic personnel Unit Typ...

Page 2: ...rating manual and to follow the instructions before you put the device into service We wish you every success for your treatment with the OPTINEB ir OPTINEB ir Microprocessor Controlled Mobile Ultraso...

Page 3: ...amme 8 2 1 Features of the first programme P1 8 2 2 Features of the second programme P2 8 2 3 Features of the third programme P3 8 2 4 Features of the fourth programme P4 8 2 5 Features of the fifth p...

Page 4: ...device if it is used by a third party or not used according to the instructions Important information is highlighted by the following terms WARNING Important safety information on hazards that can lea...

Page 5: ...persons 3 Only use the device for its intended purpose as specified in these operating instructions Under no circumstances should accessory parts be used that are not recommended by the manufacturer...

Page 6: ...that is intended to produce aerosols in various particle sizes by using different baffle plates see Section 3 2 This ensures an optimal and identifiable deposition of your medication 3 1 Function duri...

Page 7: ...d by using different baffle plates Baffle plate 1 ON 117G green color MMAD 2 3 m alveolar deposition Baffle plate 2 ON 117B blue color MMAD 3 2 m alveolar deposition Baffle plate 3 ON 117R red color M...

Page 8: ...Component parts 8 GERMAN 4 0 The most important component parts of your OPTINEB ir ultrasonic nebulizer WATSON LABORATORIES INC IPR2017 01621 Ex 1006 p 8 of 33...

Page 9: ...lter housing with valve and filter membrane Item ON 101 A9 1 Filter membrane Item ON 109 A10 Medication cup Item ON 102 Sterile medication cup Item ON 102S A11 Multifunction lamp A12 Display screen A1...

Page 10: ...his can lead to significant impairment of the performance of the device and even to complete malfunction 5 03 Insert a sterile medication cup A10 with the tip facing downwards into the ultrasonic nebu...

Page 11: ...2 1 5 09 Use of OPTINEB ir in the inspiration branch of the ventilation system Can be used with all ventilators Now integrate the OPTINEB ir ultrasonic nebulizer into the inspiration branch of your ve...

Page 12: ...the Luer Lock connection A6 of the OPTINEB ir ultrasonic nebulizer Now connect the OPTINEB ir A1 ultrasonic nebulizer by adaption with the hose system for the aerosol inlet close to the patient A19 wi...

Page 13: ...stem T piece between climate control filter and tube sterile hose system incl control line angle piece 60cm creased tube and T piece A19 IMPORTANT Use only sterile medication cups A10 for use in the v...

Page 14: ...t immerse the device into water or any other fluid Do not use the device if it has fallen into water Immediately pull out the mains plug 6 2 Direct current outlet Connect the car adapter A18 to the de...

Page 15: ...after the display A12 of the OPTINEB ir shows the letter combination LB may the battery be charged again When the battery charge is 100 operation of the ultrasonic nebulizer OPTINEB ir of approx 40 mi...

Page 16: ...s up yellow and PA pause appears on the display In order to restart nebulization press the Start Stop key A15 again The display changes from PA in the time mode the multifunction lamp lights up green...

Page 17: ...ntrolled inhalation with constant output P 5 Not suitable P 6 Intermittent operating mode auto mode Active Passive operation volume controlled mode 8 1 Programming mode only for authorized persons 1 P...

Page 18: ...d 8 2 2 Features of the second program P2 Program 2 was developed for the nebulization of special medications Non adjustable nebulization time max 12 minutes Time indication on the display runs from 0...

Page 19: ...s of the fourth program P4 Corresponds to Program P3 but without the initial intermittent time period The user is not able to change the program parameters 8 2 5 Features of the fifth program P5 Progr...

Page 20: ...econds without pressing any keys Then the set time will be automatically saved Now the active phase is set In order to now set the passive phase please perform the same steps Hold down both the Start...

Page 21: ...on using an additional example If you for example set the active phase to 10 seconds and the passive phase to 0 the seconds of the active phase are automatically converted to minutes in this case 10 m...

Page 22: ...The remaining quantity left in the medication cup depends on the selected program P1 approx 0 5 1 5 ml remaining quantity P2 approx 0 5 1 5 ml remaining quantity P3 P4 P5 P6 approx 0 5 ml remaining qu...

Page 23: ...drocarbons ammonia amines or alkaline aqueous solutions Temperature resistance of the plastic used The plastic which we use is temperature resistant up to 134 C Sterilization procedure The following s...

Page 24: ...upside down on an absorbent pad and allow it to air dry in this position The ultrasonic oscillator at the base of the water reservoir should be carefully cleaned with a cotton bud 1 2 times per week...

Page 25: ...ad to deformation of the medication cups A10 These micro deformations of the medication cup A10 can lower the output of the ultrasonic nebulizer considerably 12 0 Servicing The OPTINEB ir ultrasonic n...

Page 26: ...no contact fluid 1 No contact fluid in reservoir 1 Fill with 45 ml of contact fluid cover sensor 2 Has been filled with sterile or purified water 2 Add approx 1 ml tap water to the 45 ml of contact f...

Page 27: ...te any aerosol 1 Several medication cups used 1 Only use one medication cup 2 Used or damaged medication cups used 2 Use new medication cups 3 Device is not connected to power supply 3 Connect device...

Page 28: ...INEB ir 1 ON 100HPA High performance battery for OPTINEB ir 1 ON 100N Plug in power supply 110 220 V 1 ON 100Z 12 V motor vehicle adapter 1 ON 113 Leather pouch for OPTINEB ir 1 ON B 117 Stainless ste...

Page 29: ...cone hose 10 5 cm 1 ON B 109 Adult s silicone hose 20 0 cm 1 ON B 110 Neonatal adapter 22 ID 9 11 mm 1 ON B 111 Children s adapter 22 ID 9 13 mm 1 ON B 112 Neonatal adapter 22 AD 9 11 mm 1 ON B 113 Ch...

Page 30: ...n GmbH Kreuzfeldring 17 63820 Elsenfeld GERMANY Phone 49 0 6022 610 62 0 Fax 49 0 6022 64 98 12 E mail nebu tec t online de Web http www nebu tec de Product name OPTINEB ir Model Type ON 100 2 2 4 MHz...

Page 31: ...card Garantiekarte Warranty Card Typ Type VN 100 4 2 4 MHz Geratenummer Serial Number Kaufdatum Purchase Date Benutzer Handler User Dealer Name Strase Adresse Street Address PLZ Ort Zip Code Town Land...

Page 32: ...WATSON LABORATORIES INC IPR2017 01621 Ex 1006 p 32 of 33...

Page 33: ...are that all statements made herein of my own knowledge are true and that all statements made on information and belief are believed to be true and further that these statements were made with knowled...

Reviews: