7.1.1
Star pattern
In a typical setup the units are placed in a star pattern, i.e. the Master is
in the center of the Slaves, see below.
nea
t
1
1
1
1
S1
S2
S3
R
M
Picture 6.
SMOKE units in a Star pattern setup
#
Denomination
M
Master
S1
Slave
S2
Slave
S3
Slave
R
Radio Receiver (in this example a Care Phone NEO)
Table 7.
Part denominations used in this user manual
In this configuration all Slaves must be in radio range from the Master,
which in turn must be in radio range from the Radio receiver. Radio range
between the Master and receiver can be extended with REPO and/or
REPO+ (optional accessory).
Example of star pattern
Look at the setup in Picture 6; “SMOKE units in a Star pattern setup”
above.
When smoke is detected, e.g. by Slave
S2
the slave sounds with the
acoustical signal, the LED is flashing red and a smoke alarm is sent. This
smoke alarm is received by the Master
M
and relayed to the radio receiv-
er
R
(a Care Phone NEO).
S1
and
S3
also starts sounding but without flashing its LED.