background image

Nearus USB 2.0 Camera Manual 

 

NU-350-USB2PTZ-B

Summary of Contents for NU-350-USB2PTZ-B

Page 1: ...Nearus USB 2 0 Camera Manual NU 350 USB2PTZ B ...

Page 2: ...agnetic interference Do not view bright images halogen lights the sun etc for long periods Do not clean the camera with active chemicals or corrosive agents Remove dust or dirt from the lens with a blower or use an eyeglass cleaner with a clean microfiber cloth Do not disassemble the camera In case of trouble contact tech support Box Contents 1080p color video conference camera 12V 2 0A DC power a...

Page 3: ...wires and power wires to the junction box Thread the field wires through the L bracket s wire access hole and secure the L bracket to the junction box using the 4 long screws Mount the camera to the L bracket by inserting the 2 short screws from the underside of the bracket Connect the USB 2 0 cable power connection and control wire to the back of the camera Connect USB 2 0 cable to the PC and sel...

Page 4: ...a Control Software is available on the Support tab of the product page To install and use this software connect your local laptop to the camera with USB 2 0 cable a VISCA to RS 232 adapter Confirm the camera s COM port by going to Control Panel Device Manager Ports or push the Windows key Pause Break Expand the Ports tree and locate the camera s port number at the end of the line item or right cli...

Page 5: ...st the focus press Far or Near Preset Area Point the camera toward the desired viewing area type in a number in the Num field and press Set Enter a number in the Num field and press Call to shift the camera to the saved viewing parameters Enter a number in the Num field and press Clear to remove that preset Firmware Update Area Click Import the file to locate the new firmware and Start to begin th...

Page 6: ...32 or RS 485 match the controlling pins to the pins on the provided VISCA cable RS 232 IN Pinout Chart Use VISCA protocol 9600 baud Pin Function 1 DTR In 2 DSR In 3 TXD In 4 GND 5 RXD In 6 GND 7 IR Commander Signal Output 8 N A RS 485 OUT Pinout Chart Use PELCO D protocol 38400 baud Pin Function 1 Data Transmission Ready Out 2 Data Set Ready Out 3 Transmit Data Out 4 Ground 5 Receive Data In 6 Gro...

Page 7: ...ast Zoom Out function Zoom Slow Slow Zoom In function Zoom Slow Slow Zoom Out function Auto Auto focuses the image Manual Enables manual focus Far Auto zooms far Near Auto zooms near Directional Pad Up Down Left Right Pan Begins panning L Limit Sets the left limit point for boundary scans Scan Enables disables automatic scanning R Limit Sets the right limit point for boundary scans Home Returns th...

Page 8: ...F 01 04 FF Pan Left fast 81 01 09 01 09 09 01 03 FF Preset 4 Call 81 01 04 3F 02 04 FF Pan Right slow 81 01 06 01 03 03 02 03 FF Preset 5 Set 81 01 04 3F 01 05 FF Pan Right fast 81 01 06 01 09 09 02 03 FF Preset 5 Call 81 01 04 3F 02 05 FF Pan Stop 81 01 06 01 09 09 03 03 FF Zoom In Tele 81 01 04 07 02 FF Zoom Stop 81 01 04 07 00 FF Zoom Out Wide 81 01 04 07 03 FF Presets Preset Function 76 Places...

Page 9: ... correct Camera Select button on the remote and try again The image fragments on iOS When using Quicktime set video quality to maximum The image is upside down or reversed Possibility 1 The Reverse button has been pressed Press Rev on the remote Possibility 2 The computer s software is causing the problem Adjust the camera image in the software Note that some software displays the image reversed i...

Page 10: ...at 1080p 30Hz IR Control Front Rear Sensors Communication EIA RS 232 EIA RS 485 both bidirectional PTZ Control Protocol PELCO D Baud 9600 38400 bps Presets 64 Save Status after Power Off Yes Pan Speed 1 120 s Tilt Speed 1 100 s Pan Rotation Angle 360 Continuous Tilt Rotation Angle 90 45 Auto Pan Scan Yes Remote Control IR Wireless Remote Control PTZ Power 12VDC 10 2A Operation Temperature 32 122 F...

Page 11: ...ty includes parts and labor repairs on all components found to be defective in material or workmanship under normal conditions of use This warranty shall not apply to products that have been abused modified or disassembled Products to be repaired under this warranty must be returned to a designated service center with an assigned return authorization RA number Contact technical support for an RA n...

Page 12: ...Version 170707 1430 ...

Reviews: