5.2 ANGLE 

Selecting the Angle Mode will enable the operator to select the angle of 
impact for the hammer.  When this mode is selected, displayed will be the 
current impact angle.  Using the Up and Down Arrow Keys other angles may 
be selected.  Angles of impact are -90 degrees (floor), 0 degrees (wall) and 
+90 degrees (ceiling).  Pressing the Enter Key will save the selected angle. 

5.3 CONFIG 

This mode is used to select the Operating Language (English or Spanish) and 
a Discard Value.  Also this mode is used to reset the Test Record Number to 
zero.  When this mode is selected, displayed will be the current language.  
Using the Up and Down Keys select the desired language and press the 
Enter Key.  Once the language has been selected all following menu items 
will be in that language.  After the language is selected displayed will be “Set 
Discard” and the current discard value.  The discard value is used to 
determine what impact data will be used when computing the Average and 
Median.  A small discard value means that impact data with only slight 
variations will be excepted when computing the Average and Median.  Larger 
discard values may include all impact data within the Test Record. 
Using the Up and Down Keys select the rebound discard value and press the 
Enter Key.  Displayed then will be “Test Num Reset? N”.  This configuration 
item is used to reset the Test Record Number to 0 if desired.  Use the Up 
Arrow Key so that the “N” is replaced with “Y” for yes and press the Enter 
Key.  All previous Test Record will be erased. 

5.4 UPLOAD 

DATA 

Stored Test Records are uploaded, sent to a PC Computer using this mode.   
Test Records stored sequentially in packets can be set to a PC Computer 
using a standard 9 pin RS232C cable. 

 

5.5.1 Upload procedure 

This mode is selected when UPLOAD DATA is displayed and the Enter 
Key is pressed.  The instrument will then display “Erase? NO”.  Using 
the Up and Down Keys the operator may choose if the stored Test 
Records are to be erased after transmission.  Pressing the Enter Key will 
start transmission.  The instrument will indicate the number of Test 
Records (packets) transmitted during the process.  When transmission is 
completed the instrument will display “Completed” “Press Enter”.  
Pressing the Enter Key will end the uploading process. 

5.5 PRINT 

Stored Test Records can be printed on an external serial printer.  A 9 pin 
RS232C cable is used to connect the instrument to the printer. 

5.5.1 Communication 

Link 

Specifications 

Data is transmitted asynchronously at 9600 Baud, 8 Data bits, 1 Stop Bit 
and No parity. 

Summary of Contents for W-D-2005

Page 1: ...W D 2005 W D 1705 W D 1505 Digital Hardness tester Instruction Manual James Instruments Inc 3727 N Kedzie Avenue Chicago IL 60618 Phone 773 463 6565 1 800 426 6500 Fax 773 463 0009 www ndtjames com...

Page 2: ...RROW 9 4 4 ENTER KEY 9 4 5 ESC KEY 9 4 5 1 Exiting Print Mode 9 4 5 2 Entering Test Routines 9 4 5 3 Exiting Test Mode 9 5 OPERATING MODES 10 5 1 REBOUND 10 5 2 ANGLE 11 5 3 CONFIG 11 5 4 UPLOAD DATA...

Page 3: ...HE FACTORY AND IS LEFT HERE FOR REFERENCE PURPOSES ONLY 16 7 1 INITIALIZE MEMORY AND TEST RECORD NUMBER 16 7 2 SET HAMMER ZERO 16 7 3 CALIBRATING THE HAMMER 16 7 4 INSTRUMENT CONFIGURATION 16 8 MAINTE...

Page 4: ...ken into account the mentioned differences in capabilities between both systems this instruction manual covers the required material for the proper use of the W D 1505 system The hardness tester is an...

Page 5: ...Do not touch the side button whilst pressing on the piston On removing the device from the surface being tested the piston once more emerges completely from the device which is immediately ready for a...

Page 6: ...sting in floors or slabs type of structures or against any horizontal surface 0 degrees when testing against walls or vertical concrete members and finally 90 degrees when testing in an overhead posit...

Page 7: ...ted area Positioning the hammer perpendicular to the surface and deploy the impact plunger pushing against the surface until the push button spring out Caution the hammer should always be held in both...

Page 8: ...to reset the Test Number to zero UPLOAD DATA This mode is used to send stored Test Records to a PC Computer PRINT The Print mode is used to select and print a specific Test Record SET CLOCK This mode...

Page 9: ...pending on the mode that the instrument is in 4 5 1 Exiting Print Mode The ESC Key is used for two different operating conditions within the printing mode If the print mode is selected and no Test Rec...

Page 10: ...Test Record by pressing the Enter Key The display will momentarily display Saving Test and then display the Average rebound value The operator may view the Median rebound value by pressing the Up Arro...

Page 11: ...he Test Record Using the Up and Down Keys select the rebound discard value and press the Enter Key Displayed then will be Test Num Reset N This configuration item is used to reset the Test Record Numb...

Page 12: ...D TYPE Rebound UNITS Number DISCARD 15 IMPACT DATA Impact 1 42 Impact 2 40 Impact 3 45 Impact 4 50 Impact 5 41 Impact 6 40 Impact 7 40 Impact 8 42 COMPUTED DATA AVERAGE 43 MEDIAN 45 MINIMUM 40 MAXIMUM...

Page 13: ...t without printing 5 6 SET CLOCK This mode is used to set the internal Real Time Clock This device keeps track of the current time and date A battery is attached to this device so that even with power...

Page 14: ...and 3 together is connected to the upload serial port If this plug is not install and error message will be displayed A string of characters COMM Test 1234 are transmitted and then received The recei...

Page 15: ...TER Key Displayed will be Mem Test Reset 6 7 TEST ADC This mode is used to test the functionality of the potentiometer mounted on the hammerhead and the Analog to Digital circuitry When this mode is s...

Page 16: ...MER ZERO and press the ENTER Key Displayed will be Cock Hammer Head Press Enter Following these instructions cock and lock the hammer or hammer fully deployed and then press the ENTER Key Displayed wi...

Page 17: ...l as 68 8 2 CLEANING THE INSTRUMENT The impact plunger and housing should be wiped using a dry and clean cloth after using the instrument Avoid the use of abrasives or solvents to clean the hammer and...

Reviews: