background image

12 | Specifications

VGA, RGBS, and YPbPr Supported Resolutions

EndoVue Parts List by Region

Horizontal 
Resolution 
(pixels)

Vertical 
Resolution 
(lines)

Vertical 
Frequency 
(Hz)

Horizontal 
Resolution 
(pixels)

Vertical 
Resolution 
(lines)

Vertical 
Frequency 
(Hz)

Horizontal 
Resolution 
(pixels)

Vertical 
Resolution 
(lines)

Vertical 
Frequency 
(Hz)

640

350

50

800

600

85.06

1280

960

60

640

350

60

1024

768i

43.48

1280

960

75

640

350

70

1024

768

50

1280

960

85

640

400

50

1024

768

59.94

1280

1024i

43.44

640

400

70

1024

768

60

1280

1024

60

640

480

50

1024

768

64

1280

1024

60.02

640

480

60

1024

768

70.07

1280

1024

75.02

640

480

67

1024

768

75.03

1280

1024

85.02

640

480

70

1024

768

84.99

1280

480p

59.94

640

480

75

1152

576

50

1280

576p

50

640

480

85.01

1152

864

60.05

1294

960

59.96

720

400

70

1152

864

70.01

1440

900

59.94

720

400

85.04

1152

864

75

1600

1200i

48.04

720

480i

29.97

1152

864

85

1600

1200

60

720

480p

59.94

1152

900

66

1920

1080p

24

720

576i

25

1280

720p

24

1920

1080p

25

720

576p

50

1280

720p

25

1920

1080p

29.97

800

600

56.25

1280

720p

30

1920

1080i

25

800

600

60.32

1280

720p

50

1920

1080i

29.97

800

600

60.38

1280

720p

59.94

1920

1080p

50

800

600

72.19

1280

960i

29.97

1920

1080p

59.94

800

600

75

1280

960

59.94

EndoVue 19"

EndoVue 21"

EndoVue 24"

EndoVue 32"

90K0050 North America

90K0060 North America

90K0070  North America

90K0080 North America

90K0051  South America

90K0061 South America

90K0071 South America

90K0081 South America

90K0052  Japan

90K0062 Japan

90K0072 Japan

90K0082 Japan

90K0053  China

90K0063 China

90K0073 China

90K0083 China

90K0054  Emerging Market

90K0064 Emerging Market

90K0074 Emerging Market

90K0084 Emerging Market

90K0055  Europe

90K0065  Europe

90K0075 Europe

90K0085 Europe

EndoVue Accessory

26B0102 EndoVue Display Stand - 19", 21", 24"

Summary of Contents for EndoVue 19"

Page 1: ...EndoVue USER MANUAL ENGLISH ...

Page 2: ......

Page 3: ...without notice NDSsi provides this information as reference only Reference to products from other vendors does not imply any recommendation or endorsement This document contains proprietary information protected by copyright No part of this manual may be reproduced by any mechanical electronic or other means in any form without prior written permission of NDSsi All trademarks are the property of t...

Page 4: ......

Page 5: ...nu Navigation 3 INPUT and MENU Buttons Open OSD Menus 3 SCROLL Button Vertical Selection Control 3 Left Right Buttons Horizontal Selection Controls 3 Input Menu 3 Display Menu 4 Picture Menu 4 Color Menu 5 Setup Menu 5 Defaults Menu 6 Image Adjustment 6 Connector Panel Overview 7 EndoVue Connector Panel 7 Connector Types 7 Data Connectors and Pinouts 7 DVI I Digital and Analog 7 VGA 8 S Video 8 Co...

Page 6: ...ii Table of Contents Electromagnetic Compatibility Tables 15 Electromagnetic Emissions 16 Electromagnetic Immunity 16 Recommended Separation Distances 17 Contact 20 ...

Page 7: ... incoming signals of various signal types to match the resolution of the LCD panel The user can make adjustments to video parameters using the front keypad of the monitor with the On Screen Display OSD interface to optimize the viewing experience for different applications To prevent fire or shock hazards do not expose this unit to rain or moisture Also do not use this unit s polarized plug with a...

Page 8: ...t complies with the hospital local and national impedance requirements A ground post is located on the back of the product to use for grounding the chassis of the unit Any such ground must be installed in accordance with applicable electrical codes The ground post location is shown in the EndoVue Connector Panel diagram on page 7 Grounding reliability can only be achieved when the equipment is con...

Page 9: ...d a system and is therefore responsible for the system to comply with the requirements of IEC or ISO safety standards If in doubt speak with a qualified technician If such equipment and other medical devices are connected to form a medical electrical system s a green light indicator shall be provided on the final ME system s to indicate that this equipment is ready for normal use Image Retention N...

Page 10: ...to the respective IEC Standards i e IEC 60950 1 for data processing equipment and IEC 60601 1 for medical equipment Furthermore all configurations shall comply with the system standard IEC 60601 1 1 Anyone who connects additional equipment to the signal input part or signal output part configures a medical system and is therefore responsible that the system complies with the requirements of system...

Page 11: ...epair and Return requires the defective unit to be returned to our service location for repair 2 Cost of shipment of the defective unit to NDS is the responsibility of the customer Cost of shipment of the repaired unit to Customer is the responsibility of NDS 3 NDS reserves the right in its sole discretion to provide Customer with a comparable refurbished replacement unit in lieu of repair of cust...

Page 12: ...r enforcement efforts customer shall be liable for all costs thereof including attorney s fees NDS reserves the right to suspend warranty coverage to any customer who is in default of payment until such payment has been made DISCLAIMER This limited product warranty sets forth your sole and exclusive remedy and NDS s sole and exclusive liability under the Standard Limited Warranty described herein ...

Page 13: ...g screw holes of the stand mounting bracket over the four hole attachment interface on the monitor back Insert one of the four provided cap screws into a screw hole and lightly tighten Repeat the process with the remaining screws and then check to confirm that the mounting bracket is flat against the back surface of the monitor before tightening all screws securely Note Mounting bracket of the sta...

Page 14: ...d OFF and disconnected from the power source Do not allow liquids to enter the interior of the unit as severe damage to the unit can result Do not use solvents such as benzene or thinner or any acid alkaline or abrasive detergents Front Glass Thoroughly wipe the front glass surface with a lint free cloth For persistent spots or smudges use a lint free cloth dampened with distilled water Do not use...

Page 15: ... press of the button To exit a menu use the SCROLL button to move the selection to the bottom menu row and then press the SCROLL button just once to highlight the menu tab where you can use the or buttons to select another menu tab Left Right Buttons Horizontal Selection Controls To adjust a parameter select the parameter row using the SCROLL button then press the or buttons to make the adjustment...

Page 16: ...Video Parameter enabled when the input is 16 9 480P 576P or interlaced Press the or buttons to select 0 The image is displayed at a size that fills the screen without losing any video information Image could be displayed as letterboxed with black bars top and bottom or left and right 1 2 3 4 5 or 6 Incrementally enlarges and crops the centered image As the image becomes larger video information is...

Page 17: ...t of the image press the or buttons Setup Menu Menu Position To select from nine preset screen locations for display of the OSD menus press the or buttons Language To select one of 18 languages Chinese Danish Dutch English Finnish French German Greek Italian Japanese Korean Norwegian Polish Portuguese Russian Spanish Swedish and Turkish press the or buttons DPMS Enable To enable or disable Display...

Page 18: ...s profile select the saved User Defaults profile and press the Brightness Contrast button The Clearing User Profile message displays while processing Image Adjustment Brightness Contrast Button Press the Brightness Contrast button once to access the Brightness control Press the button twice to access the Contrast control or press it three times to access the Backlight control Press the or buttons ...

Page 19: ... Ohm differential Analog 75 Ohm terminated VGA RGBS YPbPr HD 15 75 Ohm terminated Composite BNC 75 Ohm terminated S Video DIN 4 75 Ohm terminated Pin Signal Pin Signal Pin Signal 1 T M D S DATA 2 11 T M D S DATA 1 3 SHIELD 21 N C 2 T M D S DATA 2 12 N C 22 T M D S CLOCK SHIELD 3 T M D S DATA 2 4 SHIELD 13 N C 23 T M D S CLOCK 4 N C 14 5V POWER 24 T M D S CLOCK 5 N C 15 GND DVI I IN Only 6 DDC CLOC...

Page 20: ...escription 1 RED 6 GND RED 11 N C 2 GREEN 7 GND GREEN 12 DDC_SDA 3 BLUE 8 GND BLUE 13 HORIZ SYNC 4 N C 9 5VD 14 VERT SYNC 5 GND 10 SYNC GND 15 DDC_SCL Pin Name Description 1 GND Ground Y 2 GND Ground Y 3 Y Intensity Luminance 4 C Intensity Chrominance Pin Name Description 1 DATA Pin 2 GROUND Sleeve Pin Name Description 1 Vcc 5 VDC 2 D Minus Data Return 3 D Plus Data Transmit 4 ID 5 GND Ground 1 5 ...

Page 21: ...Power Cable P N 35X0100 contact North America and Asia Pacific customercare ndssi com Europe customercare emea ndssi com Cable Bend Radius We recommend that the bend radius of metallic cables be no less than 63 mm 2 5 inches or 7 times the diameter of the cable whichever is greater The bend radius of Fiber Optic cables should be no less than 10 times the diameter of the cable Sharper bends can dam...

Page 22: ...10 Connector Panel Overview ...

Page 23: ...2 80 in 566 x 408 x 71 mm 29 7 x 19 1 x 3 86 in 753 x 485 x 98 mm Display Weightb 10 8 lb 4 9 kg 12 5 lb 5 7 kg 14 8 lb 6 7 kg 19 4 lb 8 8kg Operating Temperature 32 95 F 0 35 C 32 95 F 0 35 C 32 95 F 0 35 C 32 95 F 0 35 C Storage Temperature 4 122 F 20 50 C 4 122 F 20 50 C 4 122 F 20 50 C 4 122 F 20 50 C Transport Temperature 4 122 F 20 50 C 4 122 F 20 50 C 4 122 F 20 50 C 4 122 F 20 50 C Operati...

Page 24: ...4 70 01 1440 900 59 94 720 400 85 04 1152 864 75 1600 1200i 48 04 720 480i 29 97 1152 864 85 1600 1200 60 720 480p 59 94 1152 900 66 1920 1080p 24 720 576i 25 1280 720p 24 1920 1080p 25 720 576p 50 1280 720p 25 1920 1080p 29 97 800 600 56 25 1280 720p 30 1920 1080i 25 800 600 60 32 1280 720p 50 1920 1080i 29 97 800 600 60 38 1280 720p 59 94 1920 1080p 50 800 600 72 19 1280 960i 29 97 1920 1080p 59...

Page 25: ... grays and light colors Adjust the Frequency until the image just fits the screen Horizontal position adjustment can be used to verify that Frequency is set correctly Line up the image on the left edge of the screen and then shift by one click to the right The image should have one column off the screen on the right side if the Frequency is set correctly Testing and Adjusting Frequency VGA RGBS YP...

Page 26: ...14 Troubleshooting ...

Page 27: ...MC guideline information provided in this manual and verification of all medical devices in simultaneous operation are required to ensure the electromagnetic compatibility and co existence of all other medical devices prior to a surgical procedure The following EMC tables are provided for your reference Electromagnetic Emissions on page 16 Electromagnetic Immunity on page 16 Recommended Separation...

Page 28: ...tatic discharge ESD IEC 61000 4 2 6 kV contact 8 kV air 6 kV contact 8 kV air The product uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment Electrical fast transient burst IEC 61000 4 4 2 kV for power supply lines 2 kV for power supply lines The product is suitable for use in all establi...

Page 29: ...cy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the product is used exceeds the applicable RF compliance level above the product should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as re orienti...

Page 30: ...18 Electromagnetic Compatibility Tables ...

Page 31: ......

Page 32: ...many 49 89 31 707 100 info novanta europe novanta com Asia Pacific Novanta Japan East Square Omori 6 20 14 Minamioi Shinagawa ku Tokyo 140 0013 Japan 81 3 5753 2466 info ndssi jp Oriental Media Center Suite 2302 Tower C No 4 Guang Hua Road Chao Yang District Beijing 100026 China 86 10 8559 7859 info ndssi com cn NDS Quality System ISO 9001 2008 and ISO 13485 2003 FDA Registration 2954921 ...