Multiple Systems:
When two or three systems are to be installed in a given OR use the following procedure:
If the Tx and Rx units have not been bonded apply power to one Tx and one Rx then follow the
Bonding Procedure
described on page
7
. Turn second Tx and Rx pair on and repeat the
Bonding
Procedure
. Turn on the third pair and repeat the
Bonding Procedure
. Tx and Rx pairs must be bonded
one pair at a time. We recommend that bonded pairs be labeled to facilitate installation and
troubleshooting.
The bar is displayed for 60 seconds at power up. The
Signal Strength
bar is automatically displayed when
the
link re-establishes after the link disconnection
. Sample
Signal Strength
bar
s
are shown below.
Excellent link quality.
Good link quality.
Acceptable link quality, some pixilation may occur.
Link down or poor link quality, frequent pixilation
and/or screen “freeze”.
The user has the
only
option to have ZeroWire G2 systems operate using the
Auto channel
setting.
The
recommendations below should be used to determine the appropriate setting.
1. ZeroWire G2 Tx and / or Rx units cannot be used with earlier Zerowire Tx and / or Rx units.
2. Up to three ZeroWire G2 systems may be operated in the same room. The transmitters and receivers
should be separated by at least 3 ft (1 m) within the room.
3. Groups of three ZeroWire G2 systems may be set in multiple rooms, providing the rooms are spaced at
least 25 ft (7.6 m) apart.
4. ZeroWire G2 Tx and / or Rx should not be installed in metal cabinets or surrounded by metallic objects,
as this will prevent the Tx from communicating with the Rx .
1
4
Summary of Contents for 90T2071
Page 1: ...High Definition Wireless Video System User manual E n g l i s h ZeroWire G2 ...
Page 2: ......
Page 4: ......
Page 7: ...iii and 2007 47 EC ...
Page 27: ...20 ...
Page 28: ...21 ...
Page 29: ...0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 22 ...