We recommend that the bend radius of metallic cables be no less than 2.5 inches (63 mm) or 7 times   
the  diameter  of  the  cable  whichever  is  greater.      Sharper  bends  may  damage  the  cable  and  /  or 
degrade the video signal.  

6

 

Display Mounted Rx Wiring diagram 

“Y Cable 

Power Supply

Connector

 

DVI Cable 

Summary of Contents for 90T2071

Page 1: ...High Definition Wireless Video System User manual E n g l i s h ZeroWire G2 ...

Page 2: ......

Page 3: ...without notice NDSsi provides this information as reference only Reference to products from other vendors does not imply any recommendation or endorsement This document contains proprietary information protected by copyright No part of this manual may be reproduced by any mechanical electronic or other means in any form without prior written permission of NDSsi All trademarks are the property of t...

Page 4: ......

Page 5: ... 4 Wiring Diagrams 6 Cable Bend Radius 6 Setup 7 Typical Installation 8 Performance 8 Positioning and Orientation 9 Non Line of Sight Operation 12 Avoiding Co Channel Interference 13 Channel Usage 14 Multi System Installation 14 Signal Strength 14 Tab 4 Troubleshooting 15 Tab 5 Specifications 16 Supported Video Modes 17 Cleaning and Disinfecting instructions 18 Tab 6 Electromagnetic Compatibility ...

Page 6: ...are no user serviceable parts inside Refer servicing to qualified service personnel This symbol cautions the user that important information regarding the operation and or maintenance of this equipment has been included Information preceded by this symbol should be read carefully to avoid damage to the equipment This symbol denotes the manufacturer This symbol denotes the manufacturer s European C...

Page 7: ...iii and 2007 47 EC ...

Page 8: ... typical installation is shown on page 8 Note The Y adapter cables are for use with displays that are powered by 24 VDC and whose power connector accepts one of the J2 connectors shown on page 4 The NDSsi ZeroWire G2 Wireless HD Video System is a paired transmitter and receiver intended for delivery of video signals over a radio frequency link to a video display during endoscopic and general surgi...

Page 9: ...SB port is used for installing updates to the Tx or Rx firmware It is not a general purpose I O port ZeroWire G2 Transmitter ZeroWire G2 Receiver The BOND button allows the bonding of a transmitter to a receiver ...

Page 10: ...om the VESA mount With the side stamped FRONT facing the front of the display slide the step bracket between the VESA mount and the back of the display until notches labeled for the display you are working with fit over the two left hand screws Replace the right hand screws with the screws provided and tighten all screws With the flat surface of a ZeroWire G2 Rx or Tx module facing the front of th...

Page 11: ...e supplied Y adapter cable Y adapter cables shown below are available for Radiance 19 24 26 and 32 displays and Endovue 24 display Y adapter cables are not available for 42 or 55 Radiance displays Power supply is shown on the following page Y adapter cable 35X0097 for Radiance 26 G2 HB 27Ultra 26 D HB and 32 Radiance Display Y adapter cable 35X0096 for 19 24 and 26 Radiance Displays and 24 EndoVue...

Page 12: ...power supply or J3 of the Y adapter connects here When using the included power supply select and install the plug adapter that matches the wall socket in your OR 5 Ault MW172KB2400B02 GlobTek GTM91120 3024 T3A ...

Page 13: ...ic cables be no less than 2 5 inches 63 mm or 7 times the diameter of the cable whichever is greater Sharper bends may damage the cable and or degrade the video signal 6 Display Mounted Rx Wiring diagram Y Cable Power Supply Connector DVI Cable ...

Page 14: ... included power supply or a Y Adapter cable to a Tx and an Rx unit See pages 4 and 5 for Y Adapter cable information and Power Connector location Once a Tx and Rx pair is bonded they remain bonded until the Tx is explicitly bonded to another Rx or the Rx is explicitly bonded to another Tx Note If a bonded pair is turned off they will automatically bond to each other when they are turned on again B...

Page 15: ... in a surgical operating room OR Use outside of an OR environment is not recommended The following steps will help you to achieve optimal performance of the ZeroWire G2 system 1 Mount both components at least 5 feet 1 5 m from the floor 2 Ideally both the transmitter and receiver should be at the same height 3 For a reliable video link the distance between transmitter and receiver should be 15 fee...

Page 16: ...installed so they are vertical within or 10 and horizontal within or 10 Vertical Alignment Vertical alignment should be within or 10 of vertical Horizontal Alignment Horizontal alignment should be within or 10 of horizontal Positioning and Orientation is continued on the following page 9 ...

Page 17: ...y at each other Separation ZeroWire G2 operates correctly with a Tx and Rx separation of up to 30 feet 10 m However in the case of most OR environments best results are achieved with a Tx and Rx separation distance of up to 8 feet 2 4 m Positioning and Orientation is continued on the following page 10 ZeroWire G2 Receiver ZeroWire G2 Transmitter Up to 8ft 2 4 m At least 5ft 1 5 m ...

Page 18: ...ive to one another Optimum link quality is achieved when the Tx and Rx are aligned at 0 relative to each other Acceptable link quality is achieved when the Tx and Rx are aligned at angles between 0 to 45 90 and 180 relative to each other Aligning the Tx and Rx at 180 relative to each other provides the least acceptable link quality 13 ...

Page 19: ...he Tx and Rx see image 1 below Preferably the surgical lights should be positioned out of the way or raised above the line of sight If an object must obstruct the line of sight the best option is to position it half way between the Tx and the Rx OR rooms whose walls and or ceiling are constructed with metal sheets may reduce ZeroWire G2 performance This condition can be mitigated by moving the Tx ...

Page 20: ...at power on Some of the factors affecting how well the ZeroWire G2 channels are isolated are listed below 1 The thickness and material of the room walls 2 The opening and closing of room doors 3 The room s ceiling structure and the materials used in its construction Notes ZeroWire G2 Tx Rx pairs must be installed in the same room Cross room operation is not supported When multiple Tx Rx pairs are ...

Page 21: ... shown below Excellent link quality Good link quality Acceptable link quality some pixilation may occur Link down or poor link quality frequent pixilation and or screen freeze The user has the only option to have ZeroWire G2 systems operate using the Auto channel setting The recommendations below should be used to determine the appropriate setting 1 ZeroWire G2 Tx and or Rx units cannot be used wi...

Page 22: ...that it is in the on position Additional Information See Power Options on pages 4 and 5 Poor or intermittent video Possible causes Remedial Action Tx and RX are spaced more than 30 feet 10 m apart Reduce the spacing between the Tx and Rx to 15 feet 5 m or less See Tx to Rx Range specification on page 16 Tx and Rx are not aligned properly See Tx Rx alignment recommendations on page 11 DVI or SDI Tx...

Page 23: ...a The effective range may vary depending upon the environment in which the product is operating Follow the product s Setup section to achieve optimum performance and range 5 G2 16 ...

Page 24: ...l mode 1920 2270 1080 1125 50 1080i60 1920 2200 1080 562 60 1080i50 1920 2640 1080 562 50 720p60 1280 1650 720 750 60 720p50 1280 1980 720 750 50 480p60 720 870 480 525 60 576p50 720 864 576 625 50 VGA 640 800 480 525 60 SVGA 800 1056 600 628 60 XGA 1024 1344 768 806 60 SXGA 1280 1688 1024 1066 60 Special camera mode 1440 1904 900 932 60 Special camera mode 1024 1124 1024 1068 30 Special camera mo...

Page 25: ...er only Remove residual detergent by wiping all exterior surfaces with a lint free cloth dampened with distilled water Allow the unit to air dry Cautions Do not allow liquids to enter the interior of the unit and do not permit exterior surfaces to come into contact with unacceptable solvents such as those listed below as severe damage to the unit may result Unacceptable solvents MEK Methyl Ethyl K...

Page 26: ... Tx or receivers Rx should not be installed in metal cabinets or surrounded by metallic objects as this will prevent the Tx from communicating with the Rx During installation the ZeroWire G2 link video quality should be tested with the Tx and Rx at different orientation angles acceptable orientation angles are shown on page 11 Non Line of Sight Operation is discussed on page 12 We recommend that t...

Page 27: ...20 ...

Page 28: ...21 ...

Page 29: ...0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 22 ...

Page 30: ......

Page 31: ......

Page 32: ...3 5753 2466 Email info ndssi jp ISO 9001 2008 and ISO 13485 2003 FDA Registration 2954921 Europe Nijverheidscentrum 28 2761 JP Zevenhuizen ZH The Netherlands Tel 31 180 63 43 56 Email info EMEA ndssi com Corporate Headquarters 5750 Hellyer Avenue San Jose CA 95138 USA Tel 408 776 0085 Toll Free 866 637 5237 Email info ndssi com ...

Reviews: