- 13 -
restart automatically (as long as the filter pump is running) whenever the swimming pool
water temperature drops 2 degrees below the set temperature.
Depending on the initial temperature of the water in the swimming pool and the air temperature,
it may take several days to heat the water to the desired temperature. A good swimming pool
cover can dramatically reduce the required length of time.
Water Flow Switch:
It is equipped with a flow switch to prevent the heat pump of running with inadequate water
flow rate. It will turn on when the pool pump runs and shuts off when the pump shuts off. If the
pool water level is more than 1m above or below the heat pump’s automatic adjustment knob,
your dealer may need to adjust its initial startup.
Time delay -
The heat pump has a built-in 3-minute start-up delay to protect the circuitry and
avoid excessive contact wear. The unit will restart automatically after this time delay expires.
Even a brief power interruption will trigger this time delay and prevent the unit from restarting
immediately. Additional power interruptions during this delay period do not affect the 3-minute
duration of the delay.
3.9 Condensation
The air drawn into the heat pump is strongly cooled by the operation of the heat pump for
heating the pool water, which may cause condensation on the fins of the evaporator. The
amount of condensation may be as much as several liters per hour at high relative humidity.
This is sometimes mistakenly regarded as a water leak.
4.
Accessories
4.1 Accessories Installation
Anti-vibration bases
1. Take out 4 Anti-vibration bases
2. Put them one by one on the
bottom of the machine like the
picture.