BNC-446
CNC LATHE
OPERATION MANUAL
NCT Ipari Elektronikai Kft.
39/95
Date: 08.10.2015
H-1148 Budapest, Fogarasi út 7.
Tel.: +36 1 467 6300
www.nct.hu
2) Assembly procedure:
a. Step 1: To mount the coolant collector& fix by screws (4 pcs).
b. Step 2: To mount the detecting plate in clockwise and then fix it with the two bolts.
c. Step 3: Mount the black cover & the drain hose below the coolant collector.
d. Step 4: Assemble the last two sensor fix plate onto coolant collector. And then activate
checking of chuck clamp/unclamp by examining CNC monitor. Please micro-adjust
the position of sensor fix plate according to the checking until CNC shown none alarm
message on screen.