2-4
Chapter 2: POST Diagnostics
Beeps
Error Message
Corrective Action
2-4-1-2 0271: Check date and time
settings
Set Time and Date
Configuration Errors
3-1-1-1 0280: Previous boot incomplete
- Default configuration used
3-1-1-2 0281: Memory Size found by
POST differed from EISA
CMOS
Possible Hardware
problem with
Motherboard or
memory
Diskette Errors
3-4-1-1 02B0: Diskette drive A error
Replace drive or correct
setup to reflect no drive
3-4-1-2 02B1: Diskette drive B error
Replace drive or correct
setup to reflect no drive
3-4-1-3 02B2: Incorrect Drive A type -
run SETUP
Replace drive or correct
setup to reflect no drive
3-4-1-4 02B3: Incorrect Drive B type -
run SETUP
Replace drive or correct
setup to reflect no drive
Cache Errors
4-2-1-1 02D0: System cache error -
Cache disabled
Replace Cache
module/Motherboard
Other Errors
4-4-1-1 02F0: CPU ID:
Replace CPU
4-4-2-1 02F4: EISA CMOS not writeable Replace
Motherboard
4-4-2-2 02F5: DMA Test Failed
Replace Motherboard
4-4-2-3 02F6: Software NMI Failed
Replace Motherboard
4-4-2-4 02F7: Fail-safe Timer NMI
Failed
Replace Motherboard
Summary of Contents for RealPOS 7458
Page 1: ...NCR RealPOS 7458 Release 1 0 Hardware Service B005 0000 1442 Issue A ...
Page 11: ...ix Revision Record Issue Date Remarks A Feb 2003 First issue ...
Page 94: ...3 70 Chapter 3 Hardware Service ...
Page 100: ...4 6 Chapter 4 Cable Routing Guide UPS Battery Cables 20521 UPS Battery Power Cable ...
Page 101: ...Chapter 4 Cable Routing Guide 4 7 Fan Cable 20384 Tension Arms Hook Cable Clamp ...
Page 108: ......
Page 109: ...B 1 Appendix B Hardware Specifications ...
Page 110: ......