background image

7882 Scanner Installation and Owner Guide

04/01

497-0419630    Release D

40 of 58

Identification Labels

The Identification Labels are molded into the bottom of the cabinet. They provide
necessary information about the unit: power requirements, radio interference
information, and applicable NCR patents.

18548

NCR Corporation

Duluth, Ga. 

30096

Complies with FDA radiation

Performance standards 21

CFR Subchapter J.

One or more of the U.S. Patents listed below apply:

4,868,375  4,797,551  4,851,667  4,235,018  
4,272,675  4,282,426, 4,679,154  5,194,722  
5,276,316  5,334,825  5,262,625  5,256,865 
5,144,114  5,065,842  5,023,818  5,459,310  
5,588,621  5,661,297  5,773,767  5,975,417

This device complies with Part 15 of the FCC Rules.  Operation is subject to
 the following two conditions:  (1) This device may not cause harmful 
interference, and (2) this device must accept any interference received 
                             including interference that may cause undesired operation.

This apparatus does not exceed the Class A limits for 
radio noise emissions set out in the Radio Interference 
Regulations of Canada.

Le présent appareil ñ émet pas de bruits radioeléctriques 
depassant les limites de la Classe A prescrites dans le 
Reglement sur le brouillage radioeléctrique du Canada.

VCCI-1

Horizontal

Vertical

.

.

Complies with FDA radiation

Performance standards 21

CFR Subchapter J.

One or more of the U.S. Patents listed below apply:

4,868,375  4,797,551  4,851,667  4,235,018  
4,272,675  4,282,426, 4,679,154  5,194,722  

5,276,316  5,334,825  5,262,625  5,256,865 
5,144,114  5,065,842  5,023,818  5,459,310  

5,588,621  5,661,297  5,773,767  5,975,417

This device complies with Part 15 of the FCC Rules.  Operation is subject to

 the following two conditions:  (1) This device may not cause harmful 
interference, and (2) this device must accept any interference received 
                             including interference that may cause undesired operation.

This apparatus does not exceed the Class A limits for 
radio noise emissions set out in the Radio Interference 
Regulations of Canada.

Le présent appareil ñ émet pas de bruits radioeléctriques 
depassant les limites de la Classe A prescrites dans le 
Reglement sur le brouillage radioeléctrique du Canada.

VCCI-1

Horizontal

Vertical

Duluth, Ga.  30096

NCR Corporation

CE Mark Applicability

This product conforms to the requirements of the following European Union (EU)
New Approach Directives.

 

89/336/EECEMC

 

73/23/EECLow Voltage

Summary of Contents for 7882

Page 1: ...7882 Scanner Installation and Owner Guide 12623 497 0419630 Release D April 26 2001 Information Products RSD Atlanta...

Page 2: ...able and current Contents Obtaining Additional Information 3 Obtaining Technical Assistance 3 NCR 7882 Scanner Mountings 4 Installation Instructions 5 Step 1 Installing Power Supply and Interface Cabl...

Page 3: ...ternational E Mail Information Products Publishing DaytonOH NCR COM US area Management Order UnitedKingdom NCR COM International MS Mail Publishing Information Products US Area SMTP Order Management U...

Page 4: ...scanner with many of the same features as the larger scanners It can be mounted horizontally in a checkstand or vertically above the checkstand Various mounts are available for the 7882 Scanner Vertic...

Page 5: ...scanner is communicating with the host terminal After verifying that everything is working correctly mount the unit in the checkstand If the NCR 7882 does not work properly refer to the problem correc...

Page 6: ...r source is being used In either case the input voltage to the NCR 7882 should be 12Vdc The NCR 7882 current never exceeds 600mA 1 Locate the Power Supply in the checkstand at least 10 inches 25 4 cm...

Page 7: ...n Cable The NCR 7882 auxiliary RS 232 port hardware is limited to the following fixed parameters Baud Rage 9600 Parity Odd Stop Bits 1 Number of Data Bits 7 Hardware Handshaking None Terminator Charac...

Page 8: ...cable before scanning any programming tags If the Interface Cable is provided as a kit rather than being included with the 7882 you can set the communication parameters by scanning the bar code on the...

Page 9: ...051 7052 7053 7054 7450 7070 1 P 1 4 1 6 C 0 1 1 0 0 4 0 RS 232 NCR 2170 7452 7445 ICL 9518 200 9520 150 MicroBilt MB 8010 Checkreader 9 Pin D Shell 6 Pin Modular 1 P 1 4 1 6 C 0 1 9 0 0 4 0 IBM Forma...

Page 10: ...0 of 58 OCIA Short Format NCR 2113 2126 7058 1 P 1 4 1 6 C 0 1 4 0 0 4 0 OCIA Long Format NCR 1255 2151 2152 2552 2557 2950 1 P 1 4 1 6 C 0 2 6 0 0 4 0 RS 232 Beetle SNI Beetle 3L 1 P 1 4 1 6 C 2 6 3...

Page 11: ...7882 Scanner Installation and Owner Guide 497 0419630 Release D 04 01 11 of 58 RS 232 Ruby Verifone Ruby 4M 1 P 1 4 1 6 C 2 5 4 0 0 4 0 RS 232 Wayne Wayne Controller 1 P 1 4 1 6 C 2 3 6 0 0 4 0...

Page 12: ...8 Levels Not On File Volume Choice 2 of 8 Levels 12 Timers Lockout Time 750 Milliseconds Restart Lockout Timer Off Active Time 15 Minutes 13 Bar Codes 1 UPC EAN Enable Version D Disable Extend UPC A T...

Page 13: ...meters 1 Baud Rate 9600 Parity Odd Stop Bits Character Length 1 Stop Bit 7 Bit Character Handshake RTS High Wait For CTS 21 RS 232 Parameters 2 BCC Options Disable Interface Control None Check Digit E...

Page 14: ...power to the 7882 sets the parameters to these values Changing the 7882 program is accomplished by scanning the proper sequence of programming tags which are included with the unit Following are thre...

Page 15: ...is communicating properly with the host terminal continue with the installation Note For maximum performance full size labels must be used The UPC Symbol Specification Manual gives the exact size requ...

Page 16: ...r Color Contrast Red Bar Code On Red Background The readability of a label depends on variables such as size placement color paper type ink viscosity and package coatings The middle of a printing run...

Page 17: ...15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference...

Page 18: ...e output area on the checkstand 16012 Typical Installation Hyper Super Market Scan Zone Horizontal Installation Horizontal Vertical Pass by Scanning This installation is used where the checkstand is n...

Page 19: ...toward the top of the scanner then bags the item all in one motion 16014 Typical Installation Specialty Store Scan Zone Vertical Installation Vertical Vertical Presentation Scanning from Bottom This i...

Page 20: ...nting Bracket There are round recesses in each side of the cabinet that accept the rubber feet Remove the paper backing from the rubber feet and stick them to the cabinet in the round recesses Plastic...

Page 21: ...Plastic Top Plate in case something falls on the assembled unit DC Plastic Top Plate Latch Clip 18749 NCR 7882 Mounting Screw Power Cable Interface Cable Vertical Mounting Bracket Laser Scan Directio...

Page 22: ...ct Alignment High Surface Low Surface High Surface Low Surface 14231 Scanner Too Low Bad Alignment Bad Alignment Scanner Too High Checkpoint Cable If you are installing and NCR 7882 Scanner with the C...

Page 23: ...checkstand that supplies power to the unit Be sure this switch is in the On position The Red Indicator is on when the 7882 is ready When the scanner reads a bar code the Red Indicator turns off and t...

Page 24: ...nally high During normal operation the scan windows get dirty and if you permit the dirt to accumulate performance degrades to the point where the scanner cannot read bar codes Use a soft cloth to cle...

Page 25: ...lowing the first problem indication the beeps are turned off and only the Green Status Indicator flashes to identify the problem If the diagnostics identify a problem you must have the scanner repaire...

Page 26: ...otion detector Scanner reads only two labels Red flashing Green Off Off Communications is IBM 468x and scanner is off line Verify that IBM host is turned on Verify that IBM host is recognizing the 788...

Page 27: ...red operation This apparatus does not exceed the Class A limits for radio noise emissions set out in the Radio Interference Regulations of Canada Le pr sent appareil met pas de bruits radioel ctriques...

Page 28: ...d that identify the communications protocol Use the following table to determine the communication protocol Tone Communication Protocol 1 Beep Short high pitched OCIA NCR Short Datachecker 1 Beep OCIA...

Page 29: ...E SIDE VIEW C Item Flow D C D E A B C D E 8 5 8 in 21 91 cm 8 5 8 in 21 91 cm 1 16 in 0 16 cm 1 1 16 in 2 70 cm 1 2 in 1 27 cm Features F062 9 5 8 in 24 45 cm 11 5 16 in 28 73 cm 1 16 in 0 16 cm 1 1...

Page 30: ...n and Owner Guide 04 01 497 0419630 Release D 30 of 58 Checkstand Hole 7882 Scanner Flat Mount 11993 SIDE VIEW A B C D Features 8 3 4 in 22 22 cm 8 3 4 in 22 22 cm 1 16 in 0 16 cm 1 16 in 0 16 cm K012...

Page 31: ...Scale Electrical Wiring Feeder wiring and insulated ground from main service panel to distribution panel to be run in metal conduit The electrical wiring must meet all electrical codes laws and regul...

Page 32: ...d tag or a valid Hex tag to end this mode C Tone Length Milliseconds C When entering Tone Length the adjustment can be incremented upward by scanning the Hex C tag Each time you scan the Hex C tag the...

Page 33: ...50 6 1500 7 Off 0 On 1 0 0 15 1 30 2 60 3 19023A 1 3 BAR CODES 1 UPC EAN Disable 0 A Version D B Extend UPC A To EAN 13 C Enable 1 Disable 0 Extend UPC E To UPC A D Disable 0 Enable 1 Disable 0 Enable...

Page 34: ...smit Check Digit E Disable 0 Enable 1 Allow 1 or 2 Character Tags F 2 F 8 Default Disable 0 Enable 1 19025A 1 5 BAR CODES 3 Interleaved 2 of 5 Disable 0 A Bar Code Length B Value 1 C Enable 1 Range Ch...

Page 35: ...Type D 1 Common Byte Unique Identifier 0 7 5 Default Hex Character ASCII Code Chart 0 7 Hex Character ASCII Code Chart D 0 7 4 Default Hex Character ASCII Code Chart 0 7 Hex Character ASCII Code Chart...

Page 36: ...it for CTS 4 RTS High Wait for CTS 5 19029A 2 1 RS 232 PARAMETERS 2 BCC Options A Interface Control B Check Digit C Odd 0 ACK NAK 1 Disable UPC A Disable EAN 8 Disable EAN 13 Disable UPC E 0 XOn XOff...

Page 37: ...t Hex Character ASCII Code Chart 0 F Hex Character ASCII Code Chart 3 2 4 RS 232 COMMUNICATIONS OPTIONS Message Delay No Delay 0 10ms Delay 1 50ms Delay 2 19032B Normal or Eavesdrop Mode Normal 6 Eave...

Page 38: ...9 5A 5B 5C 5D 5E 5F P Q R S T U V W X Y Z _ 40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F A B C D E F G H I J K L M N O 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F 0 1 2 3 4 6 5 7 8 9 20 21 22 2...

Page 39: ...f this equipment does cause interference which can be determined by turning the equipment off and on the user is encouraged to consult an NCR service representative immediately Caution NCR is not resp...

Page 40: ...il met pas de bruits radioel ctriques depassant les limites de la Classe A prescrites dans le Reglement sur le brouillage radioel ctrique du Canada VCCI 1 Horizontal Vertical ComplieswithFDAradiation...

Page 41: ...following standard or other normative document following the provisions of the noted Directives EU Directive Harmonized Standard s 89 336 EEC EMC EN 55022 1994 A1 1995 A2 1997 EN 50082 1 Part 1 1992 I...

Page 42: ...e Clase IIa Evite la Exposici n Prolongada de la vista a la Luz del Rayo Laser IEC CLASS 1 LASER PRODUCT CDRH Class IIa Laser Product Avoid Long Term Viewing of Direct Laser Light Appareil Laser de cl...

Page 43: ...Class IIA CDRH Center for Devices and Radiological Health FDA U S A Following is the radiant energy of the laser light as applied to each of the specified requirements Maximum Radiant Power CDRH Calc...

Page 44: ...7882 Scanner Installation and Owner Guide 04 01 497 0419630 Release D 44 of 58 Programming Tags Volume Adjustment Reset...

Page 45: ...7882 Scanner Installation and Owner Guide 497 0419630 Release D 04 01 45 of 58 Default Programming Mode...

Page 46: ...7882 Scanner Installation and Owner Guide 04 01 497 0419630 Release D 46 of 58 End Save and Reset...

Page 47: ...7882 Scanner Installation and Owner Guide 497 0419630 Release D 04 01 47 of 58 Abort Diagnostic Mode...

Page 48: ...7882 Scanner Installation and Owner Guide 04 01 497 0419630 Release D 48 of 58 RS 232 Temporary Service Mode Mode 1...

Page 49: ...7882 Scanner Installation and Owner Guide 497 0419630 Release D 04 01 49 of 58 Mode 2 Reset Tallies...

Page 50: ...7882 Scanner Installation and Owner Guide 04 01 497 0419630 Release D 50 of 58 Hex 0 Hex 1...

Page 51: ...7882 Scanner Installation and Owner Guide 497 0419630 Release D 04 01 51 of 58 Hex 2 Hex 3...

Page 52: ...7882 Scanner Installation and Owner Guide 04 01 497 0419630 Release D 52 of 58 Hex 4 Hex 5...

Page 53: ...7882 Scanner Installation and Owner Guide 497 0419630 Release D 04 01 53 of 58 Hex 6 Hex 7...

Page 54: ...7882 Scanner Installation and Owner Guide 04 01 497 0419630 Release D 54 of 58 Hex 8 Hex 9...

Page 55: ...7882 Scanner Installation and Owner Guide 497 0419630 Release D 04 01 55 of 58 Hex A Hex B...

Page 56: ...7882 Scanner Installation and Owner Guide 04 01 497 0419630 Release D 56 of 58 Hex C Hex D...

Page 57: ...7882 Scanner Installation and Owner Guide 497 0419630 Release D 04 01 57 of 58 Hex E Hex F...

Page 58: ...7882 Scanner Installation and Owner Guide 04 01 497 0419630 Release D 58 of 58 Copyright 2000 by NCR Corporation...

Reviews: