10)

 

For key valve assembly sequence is the same for either Natural Gas or LP.  

 

       

Flex Line > Fitting > Valve > Elbow > Gas Supply Flex Line 

           

11)

 

Connect fuel supply line to Key Valve.  

12)

 

Perform leak test as described in this manual. Perform leak test on all fittings  
and back pressure checks for LP with media installed.  

13)

 

Install unit in enclosure.  

To reduce whistling ensure any flex line does not have sharp bends.  

 

           Key Valve Configuration

 

8)

 

Fire Pit Operation 

 

 

 

 

 

 

WARNING: 

Before use, be sure to test all gas connections for leaks.  Do not use fire pit if there is any evidence of leaking gas.  If 

leaking gas suspected, turn off the main gas supply and repair immediately. 

WARNING: 

Wind and gusty conditions will affect the flame in an unpredictable manner.  If conditions exist that are not safe for 

patrons turn the fire pit off. 

WARNING: 

Do not use fire pit if any part has been submerged under water.  Immediately call a qualified service technician to 

inspect the fire pit. 

WARNING:

 Never use any material that is non-porous and holds moisture such as gravel, pebbles, river rock, etc.  This material, 

when heated will cause the trapped moisture to boil and fracture unexpectedly.  This material is not sufficiently porous to allow 
heated steam to readily escape which can break and cause personal injury or damage.  

WARNING: 

Solid fuels shall not be burned in the fire pit.  Leaves, sticks, wood, paper, clothing, food material, should be kept 

away from the fire pit.  Make sure that there is no vegetation or other objects over the top or sides of the fire pit that could interfere 
with safe operation.  See clearances in Section 2 Selecting the Location. 

WARNING:

 If lava rock is wet, allow fire pit to burn for 45 minutes prior to coming within 15 feet of the fire pit. 

WARNING:

 When fire pit is not in operation turn off gas valve. 

WARRANTY REQUIREMENT: When not in use the fire pit must be covered at all times.

 

IMPORTANT

:   

Initial 

Start-up: 

It may be necessary to purge air in gas lines after system installation

 

 

 
 
 
 

START UP 

 

1.

 

STOP! Read the safety information on “What to do if you smell gas” (Pg. 1). 

2.

 

Confirm fire pit is clear of debris and that all covers are removed. 

3.

 

Place long handled lighter or match while burning on top of the fire pit. 

4.

 

Slowly turn “ON” gas valve. 

5.

 

After burner lights remove lighter or match. 

6.

 

Adjust flame to desired height. 

7.

 

If burner does not light turn valve off and allow gas to clear then repeat steps 3~7. 

8.

 

Never alter the design of the fire pit. 

9.

 

Never leave fire pit unattended- should be supervised by an adult familiar with emergency shut off. 

10.

 

Flammable materials should not be placed on or near the fire pit. 

11.

 

Children should be supervised when they are in vicinity of the fire pit. 

 

    

 

Summary of Contents for Match Lit

Page 1: ...maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance DANGER If yo...

Page 2: ...ucts be installed by professionals that are locally licensed by the authority having jurisdiction in gas piping We suggest that our products be serviced annually by a professional certified in the US by the National Fireplace Institute NFI as NFI Gas Specialists or in Canada by WETT Wood Energy Technical Training Installer must follow all instructions carefully to ensure proper performance and saf...

Page 3: ...Pit 48 From Structure or Combustibles Overhead Clearance Nothing Over Head Select a location with good drainage Choose a location that allows easy access for installation and maintenance of the fire pit Pick a location that allows sufficient horizontal room to enjoy the fire pit while allowing a safe distance from the heat and flame 3 Construction of the Enclosure WARNING All fire pits must have a...

Page 4: ...nd pressure Perform leak test on main gas supply Repair leaks as necessary Shut Off Gas Supply and Power to fire pit Connect fire pit to main gas supply If using flex line avoid sharp bends with flex line to prevent whistling Turn on gas supply and perform leak test on all inlet connections Repair as needed Position fire pit safely with access to all gas connections for testing Once fire pit is li...

Page 5: ...eave open Do not allow any rock to block flame opening 4 Blowout Box Do not cover blowout box vents or opening with lava rock or glass Incorrect media installation will cause the pilot flame to suffocate and turn off pit or delay main burner ignition Decorative Glass Application 1 Install your fire pit per instructions 2 Fill Pan with glass Cover Burner with 1 8 to of glass Do not over fill with g...

Page 6: ...Apply pipe dope or gas rated tape to all threads 7 Connect flex line from valve to burner see Steps 8 9 LP Gas Burner Assembly 8 LP burner assembly sequence Note Must use the LP Orifice Burner Pan Close Nipple Coupler Air Mixer Coupler Fitting Flex Line Air Mixer Natural Gas LP Gas Configuration WARNING Confirm Gas In is towards control valve or shutoff valve Installing backwards will result in se...

Page 7: ...ch can break and cause personal injury or damage WARNING Solid fuels shall not be burned in the fire pit Leaves sticks wood paper clothing food material should be kept away from the fire pit Make sure that there is no vegetation or other objects over the top or sides of the fire pit that could interfere with safe operation See clearances in Section 2 Selecting the Location WARNING If lava rock is ...

Page 8: ...causes and countermeasures to the symptoms indicated in bold Please contact your retailer or certified technician for service repair Below are some potential causes and countermeasures to the symptoms indicated in bold If still unable to resolve issue please contact your retailer or certified technician Will Not Light 1 Air in gas line If new install may take several attempts to purge air 2 Debris...

Page 9: ...t the edges of the caps fit tightly in the circle Step 1 Level the pad Level a 48 circular area of gravel or rock on compacted soil with the top of the pad being 1 below grade Fire Pit enclosure parts list 19 blocks 1 Key valve block block with hole 8 top caps Important Product Information The fire pit concrete blocks can crack due to high temperatures These blocks are manufactured to meet industr...

Reviews: