NCP Match Lit Installation & Operation Instructions Download Page 2

 

 

 

Index: 

1)

 

General Information 

2)

 

Selecting the Location 

3)

 

Construction of Enclosure 

4)

 

Installation of Fire Pit 

5)

 

Media 

Product Specific Information  

6)

 

Parts List 

7)

 

Assembly 

8)

 

Fire Pit Operation 

9)

 

Maintenance 

10)

 

Troubleshooting 

11)

 

Warranty 

 
 

 

1)

 

General Information 

 
 

Please carefully follow the instructions in this manual to prevent personal injury or property loss.  Instructions are 
updated as needed.  It is the installer’s responsibility to periodically review instruction for applicable updates. 

 

The steps listed as: 

 

WARNINGS:

  

Contains information critical to the safe installation and operation of the fire-pit. 

WARRANTY REQUIREMENT: Must be strictly followed to qualify for product warranty.  

Warranty will be void if not followed. 

IMPORTANT: Are notes and insights to help ensure product satisfaction and serviceability. 

-------------------------------------------------------------------------------------------------------------------------------------------------                                          

WARNING: 

 

It is the installer’s responsibility to ensure a safe installation and to educate the end user as to proper 

operation.  Leave this manual with the end user. 

WARNING: 

 Never

 

alter product or configuration in any way. 

WARNING: 

We suggest that our products be installed by professionals that are locally licensed by the authority having 

jurisdiction in gas piping.  We suggest that our products be serviced annually by a professional certified in the US by the 
National Fireplace Institute (NFI) as NFI Gas Specialists or in Canada by WETT (Wood Energy Technical Training).  
Installer must follow all instructions carefully to ensure proper performance and safety. Manufacturer is not responsible 
for your actions.   

WARNING

:  Product is not intended to be a starter for wood or any other combustibles.  

WARNING:  

It is the responsibility of the installer to follow ALL LOCAL CODES concerning the installation and 

operation of the fire pit.  In the absence of local codes, please follow: 

 

● Fixed piping system: The 

National Fuel Gas Code

ANSI Z223.1/NFPA 54

 or 

International Fuel Gas  

 

Code. 

 

● Electrical ground: The 

National Electrical Code, ANSI/NFPA 70

WARNING:  

Only use gas/fuel type specified for this fire pit. Verify correct gas/fuel type and pressure.  Never use an 

alternative fuel to include bio-fuel, ethanol, lighter fluid or any other fuel. 
 

             Gas pressure and type should be checked prior to use and installation. 

             

 

                ● Natural Gas Fire Pit:  

Supply Pressure: Minimum: 3.5” W.C.; Maximum: 7.0” W.C.   
 

 

                ● LP Gas: 

Supply Pressure: Minimum: 8.0” W.C.; Maximum: 11.0” W.C.   
 
 
 
 

Summary of Contents for Match Lit

Page 1: ...maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance DANGER If yo...

Page 2: ...ucts be installed by professionals that are locally licensed by the authority having jurisdiction in gas piping We suggest that our products be serviced annually by a professional certified in the US by the National Fireplace Institute NFI as NFI Gas Specialists or in Canada by WETT Wood Energy Technical Training Installer must follow all instructions carefully to ensure proper performance and saf...

Page 3: ...Pit 48 From Structure or Combustibles Overhead Clearance Nothing Over Head Select a location with good drainage Choose a location that allows easy access for installation and maintenance of the fire pit Pick a location that allows sufficient horizontal room to enjoy the fire pit while allowing a safe distance from the heat and flame 3 Construction of the Enclosure WARNING All fire pits must have a...

Page 4: ...nd pressure Perform leak test on main gas supply Repair leaks as necessary Shut Off Gas Supply and Power to fire pit Connect fire pit to main gas supply If using flex line avoid sharp bends with flex line to prevent whistling Turn on gas supply and perform leak test on all inlet connections Repair as needed Position fire pit safely with access to all gas connections for testing Once fire pit is li...

Page 5: ...eave open Do not allow any rock to block flame opening 4 Blowout Box Do not cover blowout box vents or opening with lava rock or glass Incorrect media installation will cause the pilot flame to suffocate and turn off pit or delay main burner ignition Decorative Glass Application 1 Install your fire pit per instructions 2 Fill Pan with glass Cover Burner with 1 8 to of glass Do not over fill with g...

Page 6: ...Apply pipe dope or gas rated tape to all threads 7 Connect flex line from valve to burner see Steps 8 9 LP Gas Burner Assembly 8 LP burner assembly sequence Note Must use the LP Orifice Burner Pan Close Nipple Coupler Air Mixer Coupler Fitting Flex Line Air Mixer Natural Gas LP Gas Configuration WARNING Confirm Gas In is towards control valve or shutoff valve Installing backwards will result in se...

Page 7: ...ch can break and cause personal injury or damage WARNING Solid fuels shall not be burned in the fire pit Leaves sticks wood paper clothing food material should be kept away from the fire pit Make sure that there is no vegetation or other objects over the top or sides of the fire pit that could interfere with safe operation See clearances in Section 2 Selecting the Location WARNING If lava rock is ...

Page 8: ...causes and countermeasures to the symptoms indicated in bold Please contact your retailer or certified technician for service repair Below are some potential causes and countermeasures to the symptoms indicated in bold If still unable to resolve issue please contact your retailer or certified technician Will Not Light 1 Air in gas line If new install may take several attempts to purge air 2 Debris...

Page 9: ...t the edges of the caps fit tightly in the circle Step 1 Level the pad Level a 48 circular area of gravel or rock on compacted soil with the top of the pad being 1 below grade Fire Pit enclosure parts list 19 blocks 1 Key valve block block with hole 8 top caps Important Product Information The fire pit concrete blocks can crack due to high temperatures These blocks are manufactured to meet industr...