Gas -Oriental GB – Gas Teppanyaki Jumbo Grill
FRM-PDE-03-04
Position and Fixing
1.
Authorized personnel must do the installation.
2.
Install the appliance according to National Safety Standard about gas-heated standard.
3.
Place the appliance in good ventilated room with permanent ventilation ducts to guarantee
sufficient exchange of air and keep the work place healthy.
4.
If the Gas Teppanyaki Jumbo Grill not connected to a flue, it is recommended to install it under
efficient hood, which could evacuate burned gases and cooking steams. Below is construction
type according to National Regulations:
A
1
: Appliance without fan and does not have connection to a flue or to a device for evacuating
combustion products outside the room. The combustion air and burned gas mixed in one room.
5.
Make sure that any object around or under Gas Teppanyaki Jumbo Grill does not obstruct air
volume required for combustion.
6.
Put away any flammable materials near Gas Teppanyaki Jumbo Grill.
7.
When the appliance is freestanding, keep a distance at least 10 cm from side, and rear walls.
Especially when the appliance close to wall and does not protected with fire-resistant materials
made.
8.
Install the appliance separately or side by side with other appliance according to recommended
range.
9.
Put Gas Teppanyaki Jumbo Grill on solid, flat, and horizontal floor.
10.
Adjust the height of the four feet by using brackets.
11.
Before turn the appliance ON, remove the protective film. Remove any adhesive with appropriate
solvent. Eliminate all packaging material according to national laws.
Gas Supply Connection
1.
Before installing and connecting Gas Teppanyaki Jumbo Grill to gas supply, carefully control the
fixed part of gas system, which conformed to National Building Regulation.
2.
Verify gas pipes sections to guarantee sufficient supply for all gas heated appliances. Install it in
similar condition to avoid excessive pressure drops.
3.
The pipes must be made of steel (with junctions made using white cast iron, or galvanized steel
fittings, or autogenously welded joints) or copper pipes (with mechanical joints and couplings
without seals or mastics or brazed joints).
4.
Control the gas bottle (if any) placed correctly and protected in dry area.
5.
Check whether the gas pipes can easily inspected. If the pipes installed in floor and wall, make
sure that this work done according to professional standard with reference points that make it
possible to find the pipes.
NAYATI
21
20150917